Operation Manual
2 
Important warnings 
This appliance of class 3 is designed to be built in a kitchen block. 
This appliance is produced in two versions (with and without grill): 
1. Oven 
with grill
 version CBCG (door down hinged
) 
Model description  See schene of installation 
 Oven with grill, without chimney, front flue of waste gas  Page 7, Fig. 3 
 Oven with grill, with chimney horizontal – vertical  Page 7, Fig. 4 
 Oven with grill, with chimney vertical and box for waste gas  Page 8, Fig. 5 
 Oven with grill, with chimney horizontal and box for waste gas  Page 8, Fig. 6 
Oven output (Hs)  1,2 kW  (Mn = 85 g/h, propane/butane) 
Grill output (Hs)  1,6 kW  (Mn = 115 g/h, propane/butane) 
(It is technically ensured that both parts cannot be switched on at the same time). 
2. Oven 
without grill
 version CBCO (door down hinged) 
Model description  See scheme of installation 
 Oven without grill, without chimney, front flue of waste gas  Page 7, Fig. 3 
 Oven without grill, with chimney horizontal – vertical  Page 7, Fig. 4 
 Oven without grill, with chimney vertical and box for waste gas  Page 8, Fig. 5 
 Oven without grill, with chimney horizontal and box for waste gas  Page 8, Fig. 6 
2. Oven 
without grill
 version CBCO (door hinged on the left side) 
Model description  See scheme of installation 
 Oven without grill, without chimney, front flue of waste gas  Page 7, Fig. 3 
 Oven without grill, with chimney horizontal – vertical  Page 7, Fig. 4 
 Oven without grill, with chimney vertical and box for waste gas  Page 8, Fig. 5 
 Oven without grill, with chimney horizontal and box for waste gas  Page 8, Fig. 6 
Oven output (Hs)  1,2 kW   (Mn = 85 g/h, propane/butane)
If the gas tap is scarcely moving or seizing it is necessary either to replace it or to disassemble 
the appropriate tap cone, to clean it with benzoline, to grease it with a special lubricant for taps, 
for example one produced by Klüber, Munich, type „Staburgas No 32“ and to assemble it. This 
work may be carried out only by a gas specialist.
The appliance may be installed by a qualified person only!
Before installing the appliance it is necessary to check whether local connection conditions (kind 
and pressure of gas) are in accordance with appliance settings. Appliance settings values are 
shown on the instruction label (on the appliance plate).
This appliance has to be installed and connected in accordance with the valid installation 
conditions. Special attention has to be paid to the measures for sufficient ventilation. 
Gas supplying parts and waste gas connected lines (waste gas pipe) have to be tested by 
specialist according to valid norms before the initial operation and every two years thereafter. 