Specifications

ASSEMBLY INSTRUCTIONS
Tools Needed for Assembly
pipe thread sealant (not included)
a %s" socket or open end wrench for attaching the
wheels, wheel plates and hose adapter
a 7/1_"open end wrench for attaching the air pressure
gauge
an adjustable wrench for attaching the shut-off valve
a %" open end wrench to tighten handle screws,
2. Remove the protective paper strip from the adhesive
backed rubber foot strip Attach the foot strip to the
bottom of the air tank leg. Press firmly into place,
3 Attach a wheel plate to each tank leg. See page 12,
4 Attach one wheel to each side of the air compressor,
Use the top wheel plate hote, Use one shoulder bolt
and one nut for each wheel Tighten securely..
Installing Wheels, Wheel Plates, Handles,
Rubber Foot Strip
Installing Shut-off Valve
WARNING
THE WHEELS AND HANDLE DO NOT PRO-
VIDE ADEQUATE CLEARANCE, STABILITY
OR SUPPORT FOR PULLING THE UNIT UP
AND DOWN STAIRS OR STEPS. THE UNIT
MUST BE LIFTED, OR PUSHED UP A RAMP.
1 Install the 7!a,,dia handle to the outside of the com-
pressor saddle at the control end of the outfit Line up
holes in handle with saddle holes and install two
screws, one on each side, in the holes farthest from
the handWs end., Slide shrink tubing into position on
the 3/4"dia handle as shown in photo on page 6 or
page 12. Dip in boiling water or use a heat gun to
shrink tubing on handle Stide the small handle inside
of _argehandle and lineup holes Install two remaining
screws and tighten all four screws securely
it may be necessary to brace or support one
end of the outfit when attaching the wheels,
wheel plates, and the rubber foot strip,
because the air compressor will have a
tendency to tip.
SHUT-OFF |
VALVE |
SWIVEL
CONNECTION
ADAPTER
Apply a small amount of pipe sealant (not supplied) to
the tapered pipe threads on the adapter and tighten into
the manifold Instalt the swivel connection end of the
shut-off valve to the straight threaded end of the adapter
(pipe sealant is not required) and tighten this connec-
tion See photo above
INSTALLATION AND BREAK-IN PROCEDURES
Location of the Air Compressor
Locate the air compressor in a clean, dry and well venti-
lated area, The air filter must be kept clear of obstruc-
tions which could reduce air delivery of the air
compressor. The air compressor should be located at
least 12" away from the wall or other obstructions that
will interfere with the flow of air. The air compressor head
and shroud are designed to allow for proper cooling. If
humidity ishigh a Sears air filter can be installed on the
air outlet adapter to remove excessive moisture Follow
the instructions packaged with the air filter for proper
installation,,
Lubrication and Oil
This unit needs no oiling or additional lubrication
Extension Cords
Use extra air hose instead of an extension cord to avoid
voltage drop and power loss to the motor
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding
piug, and a 3-slot receptacfe that wil! accept the plug on
the product
in good condition
no longer than 50 feet
12 gauge (AWG) or large_ (Wire size increases as
gauge number decreases 10 AWG and 8 AWG may
also be used DO NOT USE 14 or 16 AWG )