To Install Router Motor in Plunge Base (Fig. 10)
1. Turn the router motor off Fig. 10
and unplug the router from
the power source.
Place the plunge base on MotorSlot
a flat surface.
2_
3. With the back of the
plunge base facing you,
open the router-motor
clamp (A) and make sure
that the plunge action is
in the "UP" position, with
the plunge lock lever (B)
locked down.
\A
4. Align the router motor's slot with the pin in the plunge base, and lower the
router motor into the plunge base.
5. Slide the router motor into the base as far as it will go.
6. Securely close the router-motor clamp.
2.
3.
To install Router Motor in D-Handle Base (Fig. 11)
Turn the router motor off and unplug the router from the power source.
Place the D-handle base on a flat surface.
4_
5_
6.
With the back of the D-handle base facing you, open the router-motor clamp
(A).
Press in the Coarse Adjustment Knob (B) while aligning the router motor's
slot with the pin in the fixed base. Engage the motor's slot with the pin in the
base.
Slide the router motor down into the D-handle base.
When the coarse-adjustment knob is pressed in, the router motor can be
moved up or down to set coarse adjustments.
After all adjustments are made, securely close the router-motor clamp.
To Remove Router Motor From Fixed Base (see Fig. 9)
1. Turn the router motor off and unplug the router from the power source.
2. Place the router on a flat surface.
3. With the back of router facing you, open the router-motor clamp (A).
4. Push in the coarse adjustment knob (B) to release the router motor "Position
groove" (C) from the lock hook (D) in the base, while lifting the router motor
free of the base.
28084 Manual Revised 07-0712 Page 24