DiagnosticChart
i
issue. Consu/tDiagnosticChartbe/ow.
Safety reversingsensors
wire open(brokenor
disconnected)•
OR
Safetyreversingsensorswire
shortedor black/whitewire
reversed•
Doorcontrolor wire
shorted•
Safetyreversingsensors
slightlymisaligned
(dim or flashing LED).
Possible RPM sensorfailure•
Unplugto reset•
Symptom:One orboth of theIndicatorfights onthe safetyreversingsensorsdonot
g/owsteady.
Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white wires
reversed), broken or disconnected wires, replace/attachas needed.
Disconnect all wires from backof motor unit.
Removesensors from brackets and shorten sensor wires to 1-2 ft (30-60 cm) from back
each of sensor.
Reattachsending eye to motor unit using shortened wires. If sending eye indicator light
glows steadily, attach the receiving eye.
Align sensors, if the indicator lights glow replacethe wires for the sensors. If the sensor
indicator lights do not light, replace the safety reversing sensors.
.• Symptom:LEDis not lit on doorcontro/.
Inspect door control/wires for a short (staple in wire), replace as needed.
Disconnect wires at door control, touch wires together. If motor unit activates, replacedoor
control.
If motor unit does not activate, disconnect door control wires from motor unit. Momentarily
short across red and white terminals with jumper wire. If motor unit activates, replace door
control wires.
"0
Symptom:Sendingindicatorfight g/owssteadi/y, receivingindicatorfight is dim or
flashing.
Realign receiving eye sensor, clean lens and secure brackets.
Verify door track is firmly secured to wall and does not move.
Symptom:RPM Sensor= Shorttrave/ 6-8" (15-20 cm).
* Unplug unit to reset. Try to operate motor unit, check diagnostic code.
* If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM sensor.
* If motor unit doesn't operate, motor unit is overheated. Wait 30 minutes and retry. If motor
unit still will not operate replace logic board.