INSTALLATION STEP 11
install De ProtectorSystem_(SafetySensors)
Thesafety reversingsensormustbe connectedand aligned
correctlybeforethe garagedooropenerwill movein the down
direction.
IMPORTANTINFORMATIONABOUTTHESAFETY
REVERSINGSENSOR
When properly connected and aligned, the sensor will detect an
obstacle in the path of its electronic beam. The sending eye (with
an amber indicator light) transmits an invisible light beam to the
receiving eye (with a green indicator light). If an obstruction
breaks the light beam while the door is closing, the door will stop
and reverseto full open position, and the opener lights will flash
10 times.
The units must be installed inside the garageso that the sending
and receivingeyes face each other across the door, no more than
6" (15 cm) above the floor. Either can be installed on the left or
right of the door as long as the sun never shines directly into the
receiving eye lens.
The mounting brackets are designed to clip onto the track of
sectional garagedoors without additional hardware.
Besure power is not connected to the garagedoor opener
BEFOREinstalling the safety reversing sensor.
To prevent SERIOUSINJURY or DEATHfrom a closing garage
door:
Correctly connect and align the safety reversingsensor. This
required safety device MUST NOTbe disabled.
Install the safety reversing sensor so beam is NO HIGHER
than 6" (15 cm) above garagefloor.
If it is necessaryto mount the units on the wall, the brackets
must be securely fastened to a solid surface such as the wall
framing. Extension brackets (see accessories) areavailable if
needed. If installing in masonry construction, add a piece of wood
at each location to avoid drilling extra holes in masonry if
repositioning is necessary.
The invisible light beam path must be unobstructed. No part of
the garagedoor (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing.
I
I
I
I
I
I
I
I
Safety Reversing Sensor Invisible Light Beam
6" (15 cm) max. Protection Area
above floor
Safety Reversing Sensor
6" (15 cm) max.
above floor
Facingthe doorfrom insidethe garage
2O