Operator`s manual
Electrical Connections
Motor Specifications
The AC motor used in this saw is a capacitor-
start, non-reversible type having the following
specifications:
Rated H.P ............................. 1.5
Maximum Developed H.P .............. 2.75
Voltage ........................... 120/240
Amperes ............................. 12/6
Hertz (cycles) .......................... 60
Phase .............................. Single
RPM ............................... 3450
Rotation of Arbor Shaft .......... Clockwise
Power Supply
WARNING: Your saw is wired at
the factory for 120V operation. Connect
to a 120V, 15-AMP, branch circuit and
use a 15-AMP, time delay fuse or circuit
breaker. Failure to connect in this way
can result in injury from shock or fire.
If the motor is rewired for 240V opera-
tion, connect to a circuit protected by
15-AMP, dual element time delay fuse or
circuit breaker.
Your saw must be properly grounded. Not all
outlets are properly grounded. If you are not
sure that your outlet is properly grounded,
have it checked by a qualified electrician.
WARNING: If not properly
grounded this power tool can cause
electrical shock, particularly when used
in damp locations.
41LWARNIN(3: If an electrical shock oc-
curs, your reaction to the shock may
bring your hands into contact with the
blade.
_I_WARNING: To avoid shock or fire, if
power cord is worn, cut, or damaged in
any way have it replaced immediately.
If your unit is for use on less than 150V it has
a plug that looks like below. (Figure134)
O
3-Prong Plug
Grounding Prong
Properly
Grounded
Outlet
Fig. 134 - Plug for Less Than 150V
This power tool is equipped with a 3-conduc-
tor cord and grounding type plug which has a
grounding prong listed by Underwriters'
Laboratories. The ground conductor has a
green jacket and is attached to the tool hous-
ing at one end and to the ground prong in the
attachment plug at the other end.
This plug requires a mating 3-conductor
grounded type outlet as shown above. If you
have an outlet that is of the two prong type, it
is recommended that you have a qualified
electrician replace the it with a properly
grounded three prong outlet.
56