Installation Guide
ASSEMBLY AND INSTALLATION
1. Take the parts out of the mounting package . Screw the end of the NIPPLE (4) into the center hole of
the MOUNTING BRACKET (2) and thread both 1/8” IPS HEX NUT(5) several turns onto each end of
the NIPPLE(4) but do not tighten the 1/8” IPS HEX NUTS (5). Pull the SUPPLY WIRES (9 & 11) and
the SUPPLY GROUND WIRE (8) out from the OUTLET BOX (1) and attach the MOUNTING
BRACKET (2) assembly to the OUTLET BOX (1) using the slotted holes of the MOUNTING
BRACKET (2) and the MOUNTING SCREWS (3) provided.
2. Adjust the length of STEEL WIRES (21) by pushing the KNOB (20).
3. Feed the POWER CORD (22) up through the CONNECTOR (16), CANOPY (15) and NIPPLE (4).
4. Attach the power supply wires to the fixture lead wires by connecting the BLACK SUPPLY WIRE (9)
to the SMOOTH FIXTURE LEAD WIRE (10) and the WHITE SUPPLY WIRE (11) to the RIBBED
FIXTURE LEAD WIRE (12). Loop the FIXTURE GROUND WIRE (7) around the GROUND
SCREW (14) of the MOUNTING BRACKET (2). (Note: Be sure to provide an extra 3” length of the
GROUND WIRE(7).) Connect the remaining FIXTURE GROUND WIRE (7) to the SUPPLY
GROUND WIRE (8) using a WIRE CONNECTOR (13). Place wiring and connections inside the
OUTLET BOX (1).
5. Place the CANOPY (15) over the OUTLET BOX (1) and secure it in place by screwing the
CONNECTOR (16) onto end of the NIPPLE (4).
6. Slide the CANDLE SLEEVES (18) over the SOCKETS (17).
7. Screw light bulbs into the sockets and make sure they do not exceed the maximum wattage
specified on the fixture’s wattage rating label, MAXIMUM 60W.
INSTALLATION IS NOW COMPLETED
ASSEMBLY & INSTALLATION
INSTRUCTIONS FOR #44975-GT
Please read carefully and save these instructions, as you may need them at a later date.
GENERAL
All electrical connections must be in accordance with local and National Electrical Code (N.E.C.) standards. If
you are unfamiliar with proper electrical wiring connections obtain the services of a qualified electrician.
Remove the fixture and the mounting package from the box and make sure that no parts are missing by
referencing the illustrations on the installation instructions.
CAUTION
Turn off the main power at the circuit breaker before installing the fixture, in order to prevent possible shock.
1. OUTLET BOX
2. MOUNTING BRACKET
3. MOUNTING SCREW
4. NIPPLE
5. 1/8” IPS HEX NUT
6. SCREW COLLAR LOOP
7. FIXTURE GROUND WIRE
8. SUPPLY GROUND WIRE
FIG.
9. BLACK SUPPLY WIRE
10. SMOOTH FIXTURE LEAD WIRE
11. WHITE SUPPLY WIRE
12. RIBBED FIXTURE LEAD WIRE
13. WIRE CONNECTOR
14. GROUND SCREW
15. CANOPY
16. THREADED RING
17. SOCKET
18. CANDLE SLEEVE
19. FIXTURE BODY
20. KNOB
21. STEEL WIRE
22. POWER CORD