Specifications

CPI Communications, Inc. • 941 Hensley Lane • Wylie, TX 75098-4909
Phone (972)429-7160 • (800) 869-9128 • FAX (888) 437-5360 or (972) 429-7165
LE Series Specifications
Power Requirements 12 VDC to 16 VDC @ 35 mA idle, 175 mA maximum. Fused on circuit board.
Receive Audio Input Level 88 mVRMS to 880 mVRMS to provide full speaker output.
Audio Output to Speaker 1 Watt into 8 ohms with 13.8 VDC supply or using -WP option.
Transmit Audio Output 2 mVRMS to 565 mVRMS into 600 ohms.
Frequency Response +/- 3dB from 300 to 3000 Hz. 1000 Hz reference.
Dimensions 9" x 4" x 7" inches
Weight LE10 - 3 lbs, LE20 - 4 lbs, LE30 - 3 lbs, LE40 - 4 lbs. Option -WP - 1 lbs.
Connections Screw terminal block for radio connections. 4 pin modular jack for handset. 6 pin
for desk microphone.
PTT Output Solid state to ground, can sink up to 2.5 amps. Keying to plus voltage available as
an option.
Monitor Output Normally closed or normally open relay contacts activated by hook switch or
optional push button.
F1/F2 Select (Optional) Latched or momentary pulsed N.O. or N.C. relay contacts.
Intercom (Optional) Optional momentary push button activated circuit that allows audio transmissions
between local extensions with out keying the radio. May be used on or off-hook.
Installation Considerations
The LE series local extension will work with any radio
system that will accept a 2 mVRMS to 565 mVRMS mic
audio input level and provide an 88 mVRMS to 880
mVRMS receive audio output level.
If the radio is going to be used as a control point, the receive
audio should be taken from a point after the squelch circuit
that is unaffected by the radio's volume control.
If the radio is not going to be used as a control point,
speaker output may be used by setting the radio's volume
control for a level that falls into the above range.
The LE series requires 12 to 16 VDC @ 175 mA. This may
be supplied from a central source at the radio site using a
conductor in the hook-up cable or by using the -WP option.
18 to 22 gauge multi-conductor cabling is recommended
with the number of conductors determined by the application
and options installed.
A minimum configuration will use 6 conductors, a maximum
will use 12.
Options
-M Push button CTCSS disable. (Monitor)
-I Push button intercom. May be used on or off-hook
to communicate with other local extensions with out
keying radio.
-2F Push button selectable momentary or latching
relay output for frequency selection. LED indicators show
selected channel.
-WP Wall plug-in transformer power pack.
-WM Wall mount kit. Includes snap on bracket for
remote and wall mount plate and hardware.
-DE 12 key DTMF encoder.