After the rst successful Export, an “Import” button becomes available in the “DSG1 Perma-
nent local settings”. The Import function applies the DSG1’s editable default settings (startup
frequency, mode and level for each band, transmission activation and startup PRN). These
settings are effective immediately, and they become the new default settings for the next
startup.
NOTE
The DSG1 will always try to connect to the CPAT FTP server. If it succeeds, the
DSG1 will download the active parameters le and overwrite the current one.
To avoid this, do not connect the DSG1 to the Internet until the parameters
have also been set on the CPAT database and stored on the FTP server.