6.3
Spiral mixer model CPMel
The CPMEL model can control the machine functions through programmable
settings. It can also control the Water Doser and the Thermic probe according to the
settings programmed by the user.
When reading this paragraph, refer to picture 5.2 on pag.24
• Connect the feeling cable to the electric connection and turn the main on-off
switch to position “I”.
• Be sure the emergency button is not pressed.
• Be sure that the protection grid (fig. 2.1 at pag.13) is lowered onto the
bowl
6.3.1 TECHNICAL CHARACTERISTICS
Software SMDO.01a
Water inlet 1/2 "
Maximum entry water temperature 55° C
Maximum entry water pressure 5 bar
Minimum entry water pressure 1 bar
Maximum dosing 999,9 l
Dosing precision ±1%
Water delivery at 1 bar 25 l/min.
Water delivery at 5 bar 55 l/min.
Tension 12V C.A.
Frequency 50/60 Hz
Power 10 VA
6.3.2 DOSER, INSTALLATION
In case of hard water ( high percentage of calcium ) it is advisable to use a water
softner. This equipment must be programmed in order to leave a residual hardness of
approximately 5 to 10 french centigrades.
6.3.3 DOSER, INSTRUCTIONS FOR USE
• Press the button : the display 1 flashes.
• Through the buttons program the desired quantity of water, this
will appear on the display 1..
• Press the button : the valve opens automatically and the dosing starts.
• It is possible to stop water outlet in any moment pressing the button
The display will show the quantity of water discharged; it is sufficient to press the
button to finish the discharge.