BDOS FUNCTION 29: GET READ-ONLY VECTOR
Entry Parameters:
Register C: lDH
Returned Value:
Register HL: R/O Vector Value
Function 29 returns a bit vector in register pair HL that indicates which drives
have the temporary Read-Only bit set. The Read-Only bit can be set only by a BDOS
Write Protect Disk call.
The format of the bit vector is analogous to that of the login vector returned by
Function 24. The least significant bit corresponds to drive A, while the most signifi-
cant bit corresponds to drive P.
3-43