Operating Instructions and Installation Instructions
16
During a lter cycle:
- Pump 2 & 3* run for 20 seconds, then:
- Pump 1 runs at low speed for the programmed number of hours (see below), and
- e ozonator is turned on.
*if installed
To set the lter cycle duration (please note you can press pump 1 to exit at any time without saving):
45 Minute Filter Cycle Time-Out:
If you turn on a pump, blower, or light during a lter cycle the cycle will be interrupted and will only resume
45 minutes after you (or the system) have turned the last active output o.
Press the Filter but-
ton to enter into your
ltration options. Your
display will show “Sett”
and from here you will
be able to choose your
settings.
Press your Filter button
again to display your
rst option. is is your
Filter Cycle Duration.
Use your arrow but
-
tons to select your Filter
Cycle Duration. You
can select from 0 to 6
hours.
Press your Filter button
again. Your display will
now show the settings
for your Filtration Fre
-
quency.
Use your arrow buttons to
adjust your Filtration Fre
-
quency. You can choose
from 1-4 times per day.
You can move backwards through the programming steps by pressing your
pump 3 button.
When you have reached the end of the programming options you can press
your program button one last time to exit the programming and begin
a lter cycle immediately or simply not press any further buttons to save
your new settings and start the rst ltration cycle at the designated time.
F 06
Sett
F 06
p
FF 02
FF02
p
Quick Reference Guide
PROGRAMMING THE FILTER CYCLES