User Manual
15 
proceeding by calling the Coyote Customer Service line at 855-520-1559.     
7.  If no rushing sound, brush soapy solution onto areas where bubbles are shown in LP tank (see picture). 
8.  If “growing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If 
leaks  cannot  be  stopped,  do  not  try  to  repair  the  regulator,  or  tank  valve,  by  yourself  and  contact  the 
Coyote Customer Service line at 855-520-1559. 
9.  Always close LP tank valve after performing leak test by turning cylinder valve knob clockwise.       
NOTE: 
When leak testing this appliance, make sure to test and tighten all loose connections. A slight leak in 
the system can result in a low flame, or a hazardous condition that could result in a fire or explosion.   
LP Gas Supply Cylinder Disconnection 
In order to disconnect the LP tank from the grill: 
1.  Turn the burner valves off.   
2.  Turn the tank valve off. (Turn shut-off clockwise to stop).   
3.  Detach the regulator assembly from the tank valve by turning the quick coupling nut counterclockwise.   
LP Tank Removal, Transport and Storage 
•  Turn OFF all control knobs and  LP tank valve. Turn coupling nut counterclockwise by hand only - do not 
use tools to disconnect. Install safety cap onto LP tank valve. Always use cap and strap supplied with valve.   
Failure  to  use  safety  cap  as  directed  may  result  in  serious  personal  injury 
and/or property damage. 
A disconnected LP tank in storage or being transported must have 
a safety cap installed (as shown).   
•  Never leave a LP tank inside a motor vehicle. (Heating of the 
vehicle  could  cause  an  increase  in  the  gas  pressure  which  may 
open  the  release  vale allowing  gas  to  escape  resulting  a  serious 
risk of fire or explosion.)   
•  Do  not  store  an  LP  tank  in  enclosed  spaces  such  as  a  carport, 
garage, porch, covered patio or other building.   
•  Do not store LP tank in an area where children play. 
LP Tank Filling 
•  Use only licensed and experienced LP dealers. 
•  LP dealer must purge tank before filling. 
•  Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank will vary by 
temperature. 
•  A  frosty  regulator  indicates  gas  overfill.  If  frosty,  immediately  close  LP  tank  valve  and  call  local  LP  gas 
dealer for assistance. 
•  Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice. 
•  To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.   
LP Tank Exchange 
•  Exchange your Type 1 cylinder for OPD safety feature-equipped replacement tank ONLY. 
•  Always keep new and exchanged LP tanks in upright position during use, transit or storage. Leak test new 
and exchanged LP tanks BEFORE connecting to grill. 