User Manual
14 
•  The system has a flow limiting device which, when activated, will limit the flow of gas to 10 cubic feet per 
hour. 
•  NEVER use grill without leak testing this connection. 
LP (Propane) Gas Supply Connection 
1.  The  tank  valve  should  be  in  the  “OFF”  position.  If  not,  turn  the  knob 
clockwise until it stops.   
2.  Make sure all burner valves are in the “OFF” position.   
3.  Always connect the gas supply regulator as follows:   
Insert  the  regulator  inlet  into  the  tank  valve  and  turn  the  coupling  nut 
clockwise until the coupler tightens up (see picture). Do not over-tighten the 
coupler. Turn the main tank valve on, and turn the burner control valves on 
the unit to the “HIGH” position for about 20 seconds to allow the air in the 
system to purge before attempting to light the burners.   
Pre-Operation Leak Testing 
1.  Do not insert any tool into the valve outlet or safety relief valve. You may damage the valve and cause a 
leak. Leaking propane may result in explosion, fire, severe personal injury, or death.   
2.  If a leak is detected at any time, or you cannot stop a gas leak, immediately close the tank’s shut-off valve 
(gas supply from LP tank to the Grill) and call LP gas supplier or your fire department!   
3.  Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the 
regulator. Have a qualified service technician leak test the grill any time a part of the gas system is 
replaced. 
Never attempt to attach this grill to the self-contained LP gas system. Do not use the grill until leak testing has 
been completed. 
Leak Testing Valves, Hose and Regulator 
1.    NEVER smoke while leak testing. 
2.  Extinguish  all  open  flames.  Never  leak  test  with  an 
open flame.   
3.  Mix a solution of equal parts mild detergent or liquid 
soap and water.   
4.  Turn all grill control knobs to OFF. 
5.  Ensure that the connections from the regulator to the 
grill and tank are tight and secure (see picture).   
6.  Completely  open  LP  tank  valve  by  turning  cylinder 
valve knob counterclockwise (right to left). If you hear 
a rushing sound, turn gas off immediately. There is a 
major  leak  at  the  connection.  Correct  before 