Side Burner Manual
11
a vehicle which may become overheated by the sun.
- Do not store LP tank in an area where children play.
LP Tank Filling
- Use only licensed and experienced dealers.
- LP dealer must purged tank before filling.
- Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane in tank will
vary by temperature.
- A frosty regulator indicates gas overfill. Immediately close LP tank valve and call local LP gas dealer
for assistance.
- Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
- To remove gas from LP tank, contact an LP dealer or call a local fire department for assistance.
Check the telephone directory under “Gas companies” for nearest certified LP dealers.
LP Tank Exchange
- Exchange your Type 1 cylinder with OPD safety feature-equipped ONLY.
- Always keep new and exchanged LP tanks in upright position during use, transit or storage. Leak
test new and exchanged LP tanks BEFORE connecting to burner.
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill
is manufactured for.
This natural gas grill is designed to operate on natural gas ONLY, at a pressure regulated at 4”
(101.6mm) water column (W.C.) when equipped with the correct natural gas orifices on the valves and a
natural gas regulator on the supply line regulated at the residential meter.
IMPORTANT: Never connect the grill to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company
representative.
Natural Gas Hose and Regulator
IMPORTANT: NEVER use grill without leak testing this connection.
Natural gas regulator model: GR120
Gas pressure: 4” (101.6mm)
Maximum rate working pressure: 1/2 Psig
Natural Gas Hook-up