Specifications
10
2.4. Operating mode
a) CTX300 with display
- Remove the 4 screws (Ref. 1 in Fig. 1)
- Remove the cover (Ref. 2 in Fig. 1)
- Gently remove the screw (Ref. 3 in Fig. 2)
- Completely remove the screw (Ref. 4 in Fig. 2)
- Turn the display circuit as shown above (Ref. 5 in Fig. 3)
- Connect the cable (see 2-3: Connections for the various types of sensors) to the connector (Ref. 6,
Fig. 3)
- Return the display circuit to its original position and replace the cover
b) CEX 300 and CTX 300 without display
- Lift the cover (Ref. 1 in Fig. 1)
- Remove the cover (Ref. 2 in Fig. 2)
and proceed to wire the sensor according to the terminal location
FIG. 1
Ref. 2
Ref. 1
FIG 2
Rep3
Rep4
FIG. 3
Ref. 6
FIG. 2
Ref. 3
Ref. 4
Ref.
5