Technical data
Distribution Unit
138--118
82
3647.DOC010302 Edition: Sept. 05, 2005
DIP--
switch
Step Display Function Push but-
ton B23
(left)
Push but-
ton B22
(right)
3 1 -- r o -- RoT output scaling choose
2 r30 Select for 30°/minute choose set
3 r100 Select for 100°/minute choose set
4 r300 Select for 300°/minute choose set
5 Gy Select for analog heading output choose set
8.1.2 Adjustments E10
DIP--
switch
Step Display Function Push but-
ton B23
(left)
Push but-
ton B22
(right)
1+2 1 20 (ad-
dress)
CAN--bus address setting of Distribution Unit.
Perform processor reset with B21 after chang-
ing address
upwards down-
wards
4 1 MAGn Magnetic compass activation
2 MAGn Bring display to flash to activate input choose set
1 nME1 NMEA channel 1 c onfiguration
1 CY.1 Adjusting Baudrate: 1/sec, 4800Bd choose set
2 CY.10 Adjusting Baudrate: 10/sec, 4800Bd choose set
3 cY.10 Adjusting Baudrate: 10/sec, 9600Bd choose set
4 CY.50 Adjusting Baudrate: 50/sec, 38.4kBd choose set
5 EHdT Select for HEHDT telegram choose set
6 CHdT Select for HCHDT telegram choose set
7 IHdG Select for HCHDG telegram choose set
8 IroT Select for TIROT telegram choose set
9 EroT Select for HEROT telegram choose set
2 nME2 NMEA channel 2 c onfiguration
1 CY.1 Adjusting Baudrate: 1/sec, 4800Bd choose set
2 CY.10 Adjusting Baudrate: 10/sec, 4800Bd choose set
3 cY.10 Adjusting Baudrate: 10/sec, 9600Bd choose set
4 CY.50 Adjusting Baudrate: 50/sec, 38.4kBd choose set
5 EHdT Select for HEHDT telegram choose set
6 CHdT Select for HCHDT telegram choose set
7 IHdG Select for HCHDG telegram choose set
8 IroT Select for TIROT telegram choose set
9 EroT Select for HEROT telegram choose set