Technical data

Distribution Unit
138--118
52
3647.DOC010302 Edition: Sept. 05, 2005
4.2.3.9 Displaying heading or speed information
This setting allows to check the heading information of selected sensor, the speed in-
formation of the Log or information about supply voltages.
OPEN
DIP--Switch B20
B23
B22
Fig.30: DIP--Switch position to adjust output of heading and speed values
Procedure:
Operation of push
button B23
Display Heading information
after switching
switch 8 (B20) into
the upper position
Sen1
xxx.x°*
1x Sen2 xxx.x°*
2x Sen3 xxx.x°*
3x Sen4 xxx.x°*
4x PLoG +/--Kts
no information with DV--bus ap-
plication
5x P--11 11VDC supply voltage
of the I/O PCB
6x P--35 35VDC operating volt-
age for the 1/6 Step
function of the I/O PCB
* Designations of SEN1 to SEN4 depends on the respective CAN bus address.
The lowest address is SEN1
-- Switch 8 of the DIP--Switch into the upper position.
-- By operating the push button B22 (right side) the display shows the heading value
(the speed or supply voltage) of the selected sensor (see table above).
-- After this check, the switch 8 has to be set into lower position.