Technical data
Distribution Unit
138--118
DISTRIBUTION
UNIT
51
3647.DOC010302Edition: Sept. 05, 2005
4.2.3.8 Selection of magnetic compass
OPEN
DIP--Switch B20
B23
B22
Fig.29: DIP--Switch position to adjust application with Magnetic compass
With this adjustment it is to determine if a magnetic compass is connected to this ap-
plication.
-- Switch 4 of the DIP--Switch (B23) into the upper position.
-- The display shows MAGn.
If this display--information blinks, then it is selected and the distribution unit is
prepared to support a magnetic compass.
-- By operating the push button B22 (right side) the selection is aborted. The display
information does not blink.
-- After adjustment, the switch 4 has to be set into lower position.
If a magnetic compass is connected to the Distribution Unit and
the setting is already performed, then the Operation Unit recog-
nized the magnetic compass automatically.
But, if an external sensor as the magnetic sensor is discon-
nected (de--installation), a POWER OFF/POWER ON procedure
has to be performed at the Operation Unit (as a RESET).