Technical data
Distribution Unit
138--118
DISTRIBUTION
UNIT
47
3647.DOC010302Edition: Sept. 05, 2005
Procedure for NMEA2:
OPEN
DIP--Switch B20
B23
B22
Fig.27: DIP--Switch position to adjust the NMEA2 interface
-- Switch 2 of the DIP--Switch into the upper position.
Number of oper-
ations of push button
B23
Display Baudrate Interface
after s witching switch 2
(B20) into the upper
position
nME1 NMEA Channel 2
1x CY. 1 4800Bd NMEA 1.0sec
2x CY.10 4800Bd NMEA 0.1sec
3x cY.10 9600Bd NMEA 0.1sec
4x CY.50 38,4kBd NMEA 0.02sec
5x EHdT HEHDT--Telegram
6x CHdT HCHDT--Telegram
7x IHdG HCHDG--Telegram
8x IroT TIROT--Telegram*
9x EroT HEROT--Telegram*
* to adjust the turn rate, see section 4.2.3.7
Meaning of the telegram abbreviations:
CY and cY means “Cycle”
CY1 = 1Hz
CY10 = 10Hz
CY50 = 50Hz
HEHDT = Heading corrected, from a Gyro compass
HCHDT = Heading corrected, from a Magnetic compass
HCHDG = Heading uncorrected from a Magnetic compass
TIROT = Turn rate from a turn rate sensor
HEROT = Turn rate from a Gyro compass