Technical data
Distribution Unit
138--118
DISTRIBUTION
UNIT
43
3647.DOC010302Edition: Sept. 05, 2005
Procedure for NMEA2:
OPEN
DIP--Switch B20
B23
B22
Fig.25: DIP--Switch position to adjust the NMEA2 interface
-- Switch 2 of the DIP--Switch into the upper position.
Operation of push
button B23
Display Interface
after switching (B20)
switch2intothe
upper position
nME2 NMEA Channel2
1x nME1.0 NMEA 1.0sec
2x nM0.1 NMEA 0.1sec
3x EHdT HEHDT--Telegram
4x CHdT HCHDT--Telegram
5x IHdG HCHDG--Telegram
6x IroT TIROT--Telegram*
7x EroT HEROT--Telegram*
*Adjustment of turn rate see section 4.2.3.7
Meaning of the telegram abbreviations:
HEHDT = Heading corrected, from a Gyro compass
HCHDT = Heading corrected, from a Magnetic compass
HCHDG = Heading uncorrected from a Magnetic compass
TIROT = Turn rate from a turn rate sensor
HEROT = Turn rate from a Gyro compass