Technical data

Distribution Unit
138--118
DISTRIBUTION
UNIT
41
3647.DOC010302Edition: Sept. 05, 2005
4.2.3.4 Adjustments of NMEA Formats
The Distribution Unit can provide for each output one of three
different data f ormats (Course bus, NMEA1 and NMEA2).
Selected format can be recognized by the respective
LED colour.
The content of the course bus format cannot be changed, but
both NMEA formats can be adjusted concerning to telegram--
type and repetition rate.
Procedure for NMEA1:
OPEN
DIP--Switch B20
B23 B22
Fig.24: DIP--Switch position to adjust the NMEA1 interface
-- Switch 1 of the DIP--Switch into the upper position.
Operation of push
button B23
Display Interface
after switching (B20)
switch1intothe
upper position
nME1 NMEA Channel1
1x nME1.0 NMEA 1.0sec
2x nME0.1 NMEA 0.1sec
3x EHdT HEHDT--Telegram
4x CHdT HCHDT--Telegram
5x IHdG HCHDG--Telegram
6x IroT TIROT--Telegram*
7x EroT HEROT--Telegram*
*Adjustment of turn rate see section 4.2.3.7