Technical data
Distribution Unit
138--118
DISTRIBUTION
UNIT
21
3647.DOC010302Edition: Sept. 05, 2005
-- Push the counterpart of the earthing insert as far as the end of the cable
shield.
-- Push the earthing insert cone below the shielding against the counterpart.
Observe a shared evenly distribution of the shielding via the cone (see Fig.12).
Wall and DIN socket
Shielding
Earthing insert
-- Cone
-- Counterpart
Seal
+ Strain relief
Washer
Counter nut
Fig.12 Making the cable entry
-- Insert the earthing insert, the seal with and the washer into the cable gland, place
the counter nut on top and hand-tighten.
-- Strip the cable cores to a length of approx. 1.5cm, twist slightly and clamp on the
cable end sleeves. Connect the cable strands in the junction box as shown in the
table below. Hand-tighten the terminal screws concerned
-- Check the connection is firm by pulling lightly.