Raytheon Anschütz GmbH Postfach 1166 D -- 24100 Kiel Germany Tel +49--4 31--30 19--0 Fax +49--4 31--30 19--501 Email Service@raykiel.com www.raytheon--anschuetz.de DISTRIBUTION UNIT Type 138--118 1 Description 2 Installation 3647.DOC010302 Edition: Sept.
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages.
Distribution Unit 138--118 DISTRIBUTION UNIT CONTENTS Page Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN--Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 1.2 Technical Data . . . . . . . . . . . . . . .
Distribution Unit 138--118 6.1 Adjustment of magnetic sonde . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 7 Maintenance and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 7.1 8 Error indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional description of DIP switch settings in the service mode . . . . . . . . . . . . .
Distribution Unit 138--118 Edition: Sept. 05, 2005 III DISTRIBUTION UNIT 3647.
Distribution Unit 138--118 3647.DOC010302 IV Edition: Sept.
Distribution Unit 138--118 DISTRIBUTION UNIT Caused by technical progress the PC--Boards of the Gyro Compass are changed. Due to that some pictures and/or procedures have been changed. Respective changes are marked with “E10”. Safety instructions Caution: z Installation, maintenance and repair work must be carried out only by properly trained and qualified staff with a good knowledge of national equipment safety regulations. Edition: Sept. 05, 2005 V 3647.
Distribution Unit 138--118 Intentionally left blank 3647.DOC010302 VI Edition: Sept.
Distribution Unit 138--118 1 DISTRIBUTION UNIT General The Distribution Unit 138--118 consists of an aluminium casting in which 2 printed circuit board are integrated. -- I/O--PCB -- Interface PCB. At the bottom of the casting there are 40 cable inlets for connecting repeaters, gyros and other heading receivers and sensors. The task of this distribution Unit is: -- Distribution of heading information to all connected heading receivers. -- System monitoring by alarm--and status messages.
Distribution Unit 138--118 1.1 CAN-Bus (CAN = Controller Area Network) CAN bus The CAN bus is a Multi-Master-Bus allowing the connection of all devices and systems regardless of their task and function. This means that any number of devices can be connected. These devices must be designed for CAN bus technology. For the CAN bus it is essential that every bus user is addressable via a unique address. This address is set within each bus user.
Distribution Unit 138--118 1.2 Technical Data 1.2.1 Mechanical Data DISTRIBUTION UNIT see Dimensional Drawing “Distribution Unit 138--118.HP005” Equipment category: 1.2.2 IP22 Electrical Data Supply Voltage: 18VDC.......40VDC Max.
Distribution Unit 138--118 1.3 Information about LED‘s, push buttons, switches, plugs and connectors of the integrated PCB‘s 1.3.1 Interface PCB and I/O PCB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 15 16 17 26 Fig.2: 3647.DOC010302 25 23 22 21 20 19 18 Interface PCB (138--118.100) 4 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 No. Designation at the Interface PCB Remark Fig.2/1 Terminal Board L1 of the Distribution Unit Connection of supply voltages for the distribution unit itself and for connected gyros, operator unit and heading receivers. Fig.2/2 LED H1 +5VDC DC/DC--Converter for CAN--Bus and Course Bus Fig.2/3 Terminal Board L1 of the Interface PCB Supply Voltage (+24V DC) for this PCB Fig.2/4 LED H7 +5VDC Course Bus Fig.2/5 LED H4 +5VDC DV--Bus Fig.
Distribution Unit 138--118 1 2 3 4 5 6 7 8 9 10 52 51 47 48 49 50 43 44 45 46 39 40 41 42 33 34 30 35 31 36 32 37 38 29 28 27 23 24 25 26 19 20 21 22 15 16 17 18 11 12 13 14 Fig.3:I/O PCB (138--118.101) 3647.DOC010302 6 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 No. Edition: Sept. 05, 2005 Designation at the I/O PCB Remark Fig.3/1 Connector B1 Connection to the Interface PCB Fig.3/2 LED H30 35V DC Voltage (Step) Fig.3/3 Push Button B40 Processor Reset Fig.3/4 LED +5V5 +5VDC for RoT--Conversion Fig.3/5 LED +5V4 +5VDC galvanically separated supply voltage Fig.3/6 LED +5V6 +5VDC for RS232C Interface (Printer) Fig.3/7 LED --15V RoT Supply voltage Fig.3/8 LED +15V RoT Supply Voltage Fig.
Distribution Unit 138--118 No. 3647.DOC010302 Designation at the I/O PCB Remark Fig.3/21 Plug B28 Output Channel 6 with 3 LED‘s blue = NMEA 2 green = NMEA 1 red = Course bus Fig.3/22 Plug B27 Output Channel 5 with 3 LED‘s blue = NMEA 2 green = NMEA 1 red = Course bus Fig.3/23 Fuse E8, 1A T Protection for Channel 8 Fig.3/24 Fuse E7, 1A T Protection for Channel 7 Fig.3/25 Fuse E6, 1A T Protection for Channel 6 Fig.3/26 Fuse E5, 1A T Protection for Channel 5 Fig.
Distribution Unit DISTRIBUTION UNIT 138--118 No. Edition: Sept. 05, 2005 Designation at the I/O PCB Remark Fig.3/46 Plug B12 with LED H3 Status--Signal with indication “SENSORALARM G1” Fig.3/47 Plug B22 with LED H13 General Alarm RESET Fig.3/48 Plug B19 with LED H10 Status--Signal with indication “GYRO SELECTED” Fig.3/49 Plug B16 with LED H7 Status--Signal with indication “MONITORALARM GYRO/TMC” Fig.3/50 Plug B13 with LED H4 Status--Signal with indication “SENSORALARM G2” Fig.
Distribution Unit 138--118 1.3.2 Terminal Board, Interface PCB and I/O PCB (E10) 1 3 3647.DOC010302 2 Fig.4: Terminal board L1 No. Designation Remark Fig.4/1 Terminal board L1 Connection for the supply voltage for the Distribution Unit itself, for the connected compasses, the Operator Unit and the heading receivers. Fig.4/2 Fuse E1 10 A, T; 24V DC--Input Gyro 1 Fig.4/3 Fuse E2 10 A, T; 24V DC--Input Gyro 2 10 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 10 11 12 13 14 15 16 17 18 19 9 20 8 7 21 6 5 22 4 23 3 24 2 25 1 30 29 Fig.5: No. Edition: Sept. 05, 2005 28 27 26 Interface PCB (138--118.100 E10) Designation at the Interface PCB E10 Remark Fig.5/1 Plug B7 CAN2--Bus Fig.5/2 Switch B32 Resistor CAN2--Bus Fig.5/3 LED H2 +5V DC CAN1--Bus Fig.5/4 LED H3 +5V DC CAN2--Bus Fig.5/5 LED H7 +5V DC Course bus Fig.5/6 LED H4 +5V DC DV--Bus Fig.
Distribution Unit 138--118 No. 3647.DOC010302 Designation at the Interface PCB E10 Remark Fig.5/9 Terminal board L1 of the Supply voltage +24V DC for the Interface PCB Interface PCB Fig.5/10 Switch B2 Course bus/NMEA (test purpose only) Fig.5/11 DIP--Switch B20 Einstellungen für die Distribution Unit Fig.5/12 Push button B23 Mode selection together with DIP-Switch B20 Fig.5/13 LED H8 Processor clock (CAN--Bus Processor) Fig.5/14 Display Fig.
Distribution Unit DISTRIBUTION UNIT 138--118 6 7 8 9 10 11 see Fig.7 12 13 14 5 4 15 3 2 Fig.6: No. 1 see Fig.8 see Fig.9 see Fig.10 I/O PCB (138--118.101. E10) Designation at the I/O PCB E10 Remark Fig.6/1 Switch B41 Test purpose only. Has to be always in closed position. Fig.6/2 Plug B2 TMC Connection IN/OUT Fig.6/3 Plug B1 Connection to the Interface PCB Fig.6/4 LED H38 35V DC for Step--function, lights up if present Fig.
Distribution Unit 138--118 2 1 3 4 5 B 39 6 Fig.7: No. 3647.DOC010302 I/O PCB (138--118.101. E10) Designation at the I/O PCB E10 Remark Fig.7/1 LED H60 not used Fig.7/2 Switch B42 not used Fig.7/3 Push button B38 no function, not used Fig.7/4 Switch B39 no function, not used Fig.7/5 Push button B37 no function, not used 14 Edition: Nov.
Distribution Unit DISTRIBUTION UNIT 138--118 3 4 5 6 7 2 1 12 Fig.8: No. Edition: Sept. 05, 2005 11 10 9 8 I/O PCB (138--118.101. E10) Designation at the I/O PCB E10 Remark Fig.8/1 Plug B16 with LED H7 Status--signal--connection with indication “MONITORALARM GYRO/TMC” Fig.8/2 Plug B19 with LED H10 Status--signal--connection with indication “GYRO SELECTED” Fig.8/3 Plug B22 with LED H13 General Alarm RESET Fig.
Distribution Unit 138--118 No. 3647.DOC010302 Designation at the I/O PCB E10 Remark Fig.8/9 Plug B14 with LED H5 Status--signal--connection with indication “SENSORALARM G3/GPS” Fig.8/10 Plug B12 with LED H3 Status--signal--connection with indication “SENSORALARM G1/GPS” Fig.8/11 Plug B15 with LED H6 Status--signal--connection with indication “SENSORALARM TMC” Fig.8/12 Plug B13 with LED H4 Status--signal--connection with indication “SENSORALARM G2/GPS” 16 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 8 9 10 7 6 5 4 11 3 2 12 1 13 Fig.9: No. I/O PCB (138--118.101. E10) Designation at the I/O PCB E10 Remark Fig.9/1 Plug B35 Connection of Course bus to the I/O PCB. Fig.9/2 Plug B9 Connection of Step--output. Fig.9/3 Fuse E11 Protection (0,25A, slow) 35V DC of the Step--output at plug B9. Fig.9/4 Plug B8 Connection of Step--output. Fig.9/5 Fuse E 10 Protection (0,25A, slow) 35V DC of the Step--output at plug B8. Fig.
Distribution Unit 138--118 (Channel 8) 4 5 (Channel 4) (Channel 7) 3 6 (Channel 3) (Channel 6) 2 7 (Channel 2) (Channel 5) 1 8 (Channel 1) 12 (Channel 9) 10 (Channel 11) 9 11 (Channel 10) (Channel 12) Fig.10: No. I/O PCB (138--118.101. E10) Designation at the I/O PCB E10 Remark Fig.10/1 Plug B 27 Fuse E5 LED 26 (red) LED 27 (green) LED 28 (blue) Fig.10/2 B 28, E 6, H 29, H 30, H 31 Output channel 6 Fig.10/3 B 29, E 7, H 32, H 33, H 34 Output channel 7 Fig.
Distribution Unit DISTRIBUTION UNIT 138--118 No. Designation at the I/O PCB E10 Remark Fig.10/9 Plug B 34 LED H 57 (red) LED H 56 (green) LED H 55 (blue) Output channel 12 to connect repeater without supply voltage. Connection and indication of the adjusted data format. LED red = Course bus LED green = NMEA 1 LED blue = NMEA 2 Fig.10/10 B 33, H 54, H 55, H 56 Output channel 11 Fig.10/11 B 32, H 51, H 52, H 53 Output channel 10 Fig.
Distribution Unit 138--118 2 Installation of the Distribution Unit 2.1 General remarks Caution When establishing cable connections ensure that the cables are disconnected from the power supply. It is essential to ensure that all cables are disconnected from the power supply, if necessary measure the voltage beforehand and/or disconnect the relevant distributor.
Distribution Unit DISTRIBUTION UNIT 138--118 -- Push the counterpart of the earthing insert as far as the end of the cable shield. -- Push the earthing insert cone below the shielding against the counterpart. Observe a shared evenly distribution of the shielding via the cone (see Fig.12). Wall and DIN socket Earthing insert -- Cone -- Counterpart Seal + Strain relief Shielding Washer Counter nut Fig.
Distribution Unit 138--118 Option: Cable connection with a screen clamp Attach the angle with cross slotted screws below the respective cable inlet at the housing. (angle and screws are part of the installation kit). Strip off the cable according to section 2.1. The screen must be led for appr. 15mm through the cable inlet (as shown). Jam the cable (screen area) with the screw-clamp at the angle and fix it with the knurled head screw. 3647.DOC010302 22 Edition: Sept.
Distribution Unit 138--118 2.1.1 DISTRIBUTION UNIT General information about establishing an earth connection In order to comply with the stringent EMC requirements, please abide by the information given below regarding cable connections. Use the cable types specified. Earth connections should be connected to the gyro compass and to the junction box. It is essential to ensure that these connections have a common reference to the ship’s earth.
Distribution Unit 138--118 2.2 Installation The distribution unit has to be mounted according to the dimensional drawing 138--118.HP005. The front cover should be removable. Please note the comment depending the internal protection at the dimensional drawing. 2.2.1 Installation of the options For installations of the options, as there are “Additional Output Box” and “AC/DC--Converter”, see service manual of the Compass STD 22 Compact.
Distribution Unit DISTRIBUTION UNIT 138--118 The installation of the power supply (AC/DC--Converter) should only be performed by an experienced electrician. The supply voltage has to be engineered as a low--security-voltage according to SELV. Plastic cover Adhesive cable tie mounts Tie wrap Fig.15 Cable connections at the AC/DC--Converter To connect the cables to the terminal board, the plastic cover has to be pulled off from the terminal board.
Distribution Unit 138--118 2.3 Connections At a Distribution Unit with DV--bus application no connections for speed and/or position should be made. CAN--bus Example: Distribution Unit DV--bus NMEA Position/Speed Log Direction/Speed For example Nautoconning All connections to terminal boards and plugs have to be made according appended drawings. Please note manufacturer recommendations depending on the cable--diameters. 3647.DOC010302 26 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 2.3.1 RS422--Interface or NMEA Interface of Heading Receiver Conclusion for the connection of NON RAYTHEON Anschütz products to the Distribution Unit: If the NMEA input interface or the coursebus input interface contains a “signal common / signal ground” connection, then this connection has to be connected to “signal common / signal ground” connection of the Distribition Unit (see principle scematic below).
Distribution Unit 138--118 2.3.2 Connection of the Options For connection of the options, as there are “Additional Output Box” and “AC/DC--Converter”, see service manual of the Compass STD 22 Compact. For connection of a UTC--signal (time--synchronisation of a connected course--printer), see section 8 seq. no. 41. For connection of an Alarm--Reset--function see respective drawings at the appendix. With this function an alarm signal can be reset centrally.
Distribution Unit DISTRIBUTION UNIT 138--118 2.3.3 Connection of DV--bus Connections have to be made according section 2.1 and appended drawings. Interface PCB: Anschlußklemme L2 Interface PCB (E10): Anschlußklemme B17 Fig.16: Edition: Sept. 05, 2005 DV--bus connection Function Terminal board L2 Plug B17 (E10) Screen A 22 1 Core A 23 2 Core A 24 3 Core B 25 4 Core B 26 5 Screen B 27 6 29 3647.
Distribution Unit 138--118 3 Switching On the Distribution Unit After connecting the supply voltage, the Distribution Unit is switched on. All direct connected devices (as there are compass, and repeater with supply voltage) to the Distribution Unit are supplied with operating voltage as well. There is no separate switch for the Distribution Unit. 3647.DOC010302 30 Edition: Sept.
Distribution Unit 138--118 4 Setting of Jumpers and Adjusting the DIP--Switches 4.1 Setting of Jumpers DISTRIBUTION UNIT Basically 3 jumpers have to be awarded. These jumpers are the terminators (resistors which terminate the CAN--bus and the DV-bus). Is a distribution Unit used as an so called “end--device” within a CAN--bus and DV--bus application, all jumpers have to be set.
Distribution Unit 138--118 Jumper B1 Programming DV--bus (never set while operation) Jumper B4 DV--bus terminator 1 2 Jumper between 1--2 has to be set, if the distribution unit is an end--device within a DV--bus application 4.1.1 Activation the termination resistors by switches (E10) Basically 3 switches have to be awarded. These switches are the terminators (resistors which terminate the CAN--bus and the DV--bus).
Distribution Unit DISTRIBUTION UNIT 138--118 DV--bus B4 CAN--bus B32 Fig.19: B31 Switches to activate the terminators Switch B32 in position ON activates the terminator for CAN1--bus Switch B31 in position ON activates the terminator for CAN2--bus Switch B4 in position ON activates the terminator for DV--bus Edition: Sept. 05, 2005 33 3647.
Distribution Unit 138--118 4.2 Setting of DIP--Switches 4.2.1 Setting of DIP--Switches for DV--bus application DIP--Switch B24 Fig.20: DIP--Switch for DV--bus application All DIP--Switches of B24 have to be switched to position “OFF”. These switches are actually not used. 3647.DOC010302 34 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.2 Setting of DIP--Switches for CAN--bus (B23) 2 (B22) 4 3 DIP--Switch 1 1 (B20) DIP--Switch 8 Display B22 B23 Fig.21: 8 7 6 5 4 3 2 1 DIP--Switch E10 DIP--Switches, display and push buttons to select and adjust different operation modes 1 = DIP--Switch B20 with 8 single switches 2 = Push button B23 to select the modes within the respective DIP--Switch settings 3 = Display 4 = Push button B22 to set selected mode Edition: Sept.
Distribution Unit 138--118 4.2.3 General information in use of the DIP--Switch and push buttons The normal operation of the all DIP--Switches is the “DOWN”--position. This means the respective switch is closed. In the upper position the respective switch is open and by this, a mode can be selected and adjusted. After a switch is set into the upper position, a mode can be selected by the the push button on the left of the display (push button B23).
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.3.2 Setting of CAN Bus address Each device within a CAN bus application has to be identified with an address. This address must not be twice within this application (bus--conflict)!! The CAN bus address is already adjusted by the manufacturer. Below mentioned procedure to adjust the address is only necessary if a second Distribution Unit should be connected.
Distribution Unit 138--118 Operate push button B21 “RESET Processor” (Fig.2/6) to acknowledge or Switch OFF an ON again voltage supply to the Distribution Unit, by this the changed address is set. Below mentioned table shows the CAN bus addressees for one or several Distribution Units. Restrictions: Address 00 must not be used!! 3647.
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.3.3 Adjustment of the 8 output channels (12 output channels --> E10) Each of the 8 (12) output channels can be set to 3 different interfaces. These interfaces are: Course bus, NMEA1 and NMEA2. With the formats NMEA1 and NMEA2 to different configurations can be adjusted, these configurations become active after selection (to the respective output channel). For adjustment of this configurations see sections 4.2.3.4 . DIP--Switch B20 OPEN B23 Fig.
Distribution Unit 138--118 Number of operations of the push button B23 Display after switching of switches 1, 2 and 3 (B20) into the upper position Chn1 1x 2x 3x HSEr nME1 nME2 4x Chn2 5x 6x 7x HSEr nME1 nME2 8x Chn3 9x 10x 11x HSEr nME1 nME2 12x Chn4 13x 14x 15x HSEr nME1 nME2 16x Chn5 17x 18x 19x HSEr nME1 nME2 20x Chn6 21x 22x 23x HSEr nME1 nME2 24x Chn7 25x 26x 27x HSEr nME1 nME2 28x Chn8 29x 30x 31x HSEr nME1 nME2 32x Chn9 33x 34x 35x HSEr nME1 nME2 36x Ch10 37x
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.3.4 Adjustments of NMEA Formats The Distribution Unit can provide for each output one of three different data formats (Course bus, NMEA1 and NMEA2). Selected format can be recognized by the respective LED colour. The content of the course bus format cannot be changed, but both NMEA formats can be adjusted concerning to telegram-type and repetition rate. Procedure for NMEA1: DIP--Switch B20 OPEN B23 Fig.
Distribution Unit 138--118 Meaning of the telegram abbreviations: HEHDT = Heading corrected, from a Gyro compass HCHDT = Heading corrected, from a Magnetic compass HCHDG = Heading uncorrected from a Magnetic compass TIROT = Turn rate from a turn rate sensor HEROT = Turn rate from a Gyro compass -- By each operation of push button B23 another format is selected and displayed. -- Each adjusted format has to be set wit push button B22 (right of the display). The set format information blinks at the display.
Distribution Unit DISTRIBUTION UNIT 138--118 Procedure for NMEA2: DIP--Switch B20 OPEN B23 Fig.25: B22 DIP--Switch position to adjust the NMEA2 interface -- Switch 2 of the DIP--Switch into the upper position. Display Operation of push button B23 after switching (B20) switch 2 into the nME2 upper position 1x nME1.0 2x nM0.1 3x EHdT 4x CHdT 5x IHdG 6x IroT 7x EroT *Adjustment of turn rate see section 4.2.3.7 Interface NMEA Channel2 NMEA 1.0sec NMEA 0.
Distribution Unit 138--118 -- By each operation of push button B23 another format is selected and displayed. -- Each adjusted format has to be set wit push button B22 (right of the display). The set format information blinks at the display. -- After adjustment of all connected channels, the switch 2 has to be set into lower position. Please note: Restrictions for NMEA channel 1 and NMEA channel 2. On selection of NMEA repetition rate of 1 second, all selected telegrams can be transmitted.
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.3.5 Adjustment of NMEA Formats (E10) The Distribution Unit can provide for each output one of three different data formats (Course bus, NMEA1 and NMEA2). Selected format can be recognized by the respective LED colour. The content of the course bus format cannot be changed, but both NMEA formats can be adjusted concerning to telegram-type and repetition rate. Procedure for NMEA1: DIP--Schalter B20 OPEN B23 Fig.
Distribution Unit 138--118 Meaning of the telegram abbreviations: CY and cY means “Cycle” CY1 = 1Hz CY10 = 10Hz CY50 = 50Hz HEHDT = Heading corrected, from a Gyro compass HCHDT = Heading corrected, from a Magnetic compass HCHDG = Heading uncorrected from a Magnetic compass TIROT = Turn rate from a turn rate sensor HEROT = Turn rate from a Gyro compass -- By each operation of push button B23 another format is selected and displayed.
Distribution Unit DISTRIBUTION UNIT 138--118 Procedure for NMEA2: DIP--Switch B20 OPEN B23 Fig.27: B22 DIP--Switch position to adjust the NMEA2 interface -- Switch 2 of the DIP--Switch into the upper position. Number of operations of push button B23 after switching switch 2 (B20) into the upper position 1x 2x 3x 4x 5x 6x 7x 8x 9x Display Baudrate nME1 Interface NMEA Channel 2 CY. 1 CY.10 cY.10 CY.50 EHdT CHdT IHdG IroT EroT 4800Bd 4800Bd 9600Bd 38,4kBd NMEA 1.0sec NMEA 0.1sec NMEA 0.
Distribution Unit 138--118 -- By each operation of push button B23 another format is selected and displayed. -- Each adjusted format has to be set wit push button B22 (right of the display). The set format information blinks at the display. -- After adjustment of all connected channels, the switch 1 has to be set into lower position. Please note: Restrictions for NMEA channel 1 and NMEA channel 2. On selection of NMEA repetition rate of 1 second, all selected telegrams can be transmitted.
Distribution Unit 138--118 4.2.3.6 Edition: Nov. 28, 2005 DISTRIBUTION UNIT Left blank 49 3647.
Distribution Unit 138--118 4.2.3.7 Scaling of RoT Output For the RoT--output an adjustment of the turn rate has to be performed. DIP--Switch B20 OPEN B22 B23 Fig.28: DIP--Switch position to adjust the turn rate Procedure: -- Switch 3 of the DIP--Switch into the upper position.
Distribution Unit DISTRIBUTION UNIT 138--118 4.2.3.8 Selection of magnetic compass DIP--Switch B20 OPEN B22 B23 Fig.29: DIP--Switch position to adjust application with Magnetic compass With this adjustment it is to determine if a magnetic compass is connected to this application. -- Switch 4 of the DIP--Switch (B23) into the upper position. -- The display shows MAGn. If this display--information blinks, then it is selected and the distribution unit is prepared to support a magnetic compass.
Distribution Unit 138--118 4.2.3.9 Displaying heading or speed information This setting allows to check the heading information of selected sensor, the speed information of the Log or information about supply voltages. DIP--Switch B20 OPEN B22 B23 Fig.30: DIP--Switch position to adjust output of heading and speed values Procedure: Operation of push button B23 after switching switch 8 (B20) into the upper position 1x 2x 3x 4x Display Heading information Sen1 xxx.x°* xxx.x°* xxx.x°* xxx.
Distribution Unit 138--118 5 DISTRIBUTION UNIT Switching OFF the Distribution Unit By switching OFF the supply voltage, the distribution unit is switched OFF. All direct connected devices to the Distribution Unit, as there are compass and repeaters with supplied voltage are switched off as well. A separate switching off of the Distribution Unit is not possible. Edition: Sept. 05, 2005 53 3647.
Distribution Unit 138--118 6 Adjustments 6.1 Adjustment of magnetic sonde This adjustment should be performed only be well trained technicians. Necessary tools and measuring instruments -- Screw driver to adjust potentiometer -- Voltmeter -- Iron tool to influence the magnetic sonde TP0 TP12 TP11 R155 E10 R113 = SCALE Switch B41 B2 Fig.31: Testpoint at the I/O PCB to adjust the magnetic sonde Switch B41 has to be closed always. Switch position to the left. 3647.DOC010302 54 Edition: Sept.
Distribution Unit 138--118 DISTRIBUTION UNIT Adjustment after installation of the magnetic sonde (see Fig.31) The Distribution Unit is in operation. Magnetic sonde is installed and connected to the Distribution Unit. -- Switch the switches 6,7 and 8 of the DIP switch B20 into the upper position “OPEN”). -- Operate push button B22 until the display shows “MAGS”. -- Operate push button B23 once; the actual heading of the magnetic sonde is displayed.
Distribution Unit 138--118 7 Maintenance and Repair The Distribution Unit is maintenance free. A repair is constrained to the exchange of the PCB‘s: I/O PCB Identnumber 138--118.101 Interface PCB 138--118.101 E10 Identnumber 138--118.103 138--118.100 E10 Operation during a repair can only be performed when the CAN--bus is terminated. It is absolute necessary that the CAN--bus is terminated correctly on both ends.
Distribution Unit DISTRIBUTION UNIT 138--118 Operate the push button B23 during an error is displayed. Two different information can be displayed after that. B22 B23 or B22 B23 Fig.33: Display to determine an error Error indication “PCB0” points to a faulty Interface PCB, an error indication “PCB1” points to a faulty I/O PCB. Measures to continue determination of the error source: PCB0 Operate both push buttons B23 and B22 at the same time. Display = “Er.01” means: Interface PCB faulty.
Distribution Unit 138--118 8 Functional description of DIP switch settings in the Service mode All data stated below should be selected and read out for servicing purposes only. In standard operation the following data has no significance. The Service Mode is switched ON with DIP--Switches 6+,7 and 8 into the upper position. DIP--Schalter B20 OPEN B23 Seq. No. 1 B22 Indications Comments, Notes UnCo = (Uncorrected Compass) = heading without speed error correction value.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 2 Indications Comments, Notes Corr = Corrected course (course taking SEC into account) DIP--Switch B20: positions 6,7 and 8 B22 1x B23 3 GYr1 = Displays corrected heading for Gyro compass 1 B22 DIP--Switch B20: positions 6,7 and 8 2x B23 If there is no “Gyro 1” connected. Edition: Sept. 05, 2005 59 3647.
Distribution Unit 138--118 Seq. No. 4 Indications Comments, Notes Addr = Displays CAN--bus address for Gyro Compass 1 DIP--Switch B20: positions 6,7 and 8 B22 3x B23 If there is no “Gyro 1” connected. 5 GYr2 = Displays corrected heading for Gyro compass 2 B22 DIP--Switch B20: positions 6,7 and 8 4x B23 If there is no “Gyro 2” connected. 3647.DOC010302 60 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 6 Indications Comments, Notes Addr = Displays CAN--bus address for Gyro Compass 2 DIP--Switch B20: positions 6,7 and 8 B22 5x B23 If there is no “Gyro 2” connected. 7 GYr3 = Displays corrected heading for Gyro compass 3 B22 DIP--Switch B20: positions 6,7 and 8 6x B23 If there is no “Gyro 3” connected. Edition: Sept. 05, 2005 61 3647.
Distribution Unit 138--118 Seq. No. 8 Indications Comments, Notes Addr = Displays CAN--bus address for Gyro Compass 3 B22 DIP--Switch B20: positions 6,7 and 8 7x B23 If there is no “Gyro 3” connected. 9 MAGS = Displays heading of magnetic compass B22 DIP--Switch B20: positions 6,7 and 8 8x B23 No heading available or heading of magnetic compass faulty No magnetic compass connected 3647.DOC010302 62 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 10 Indications MAGC = Comments, Notes Displays corrected heading or magnetic compass Deviation and variation included B22 DIP--Switch B20: positions 6,7 and 8 8x B23 No heading available or heading of magnetic compass faulty No magnetic compass connected 11 MISS = Displays Variation value B22 DIP--Switch B20: positions 6,7 and 8 9x B23 Edition: Sept. 05, 2005 63 3647.
Distribution Unit 138--118 Seq. No.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No.
Distribution Unit 138--118 Seq. No. 16 Indications Comments, Notes SrC.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 18 Indications Comments, Notes vtG.S = Speed from GPS--telegram (speed over ground) B22 DIP--Switch B20: positions 6,7 and 8 16x B23 No telegram, DV--bus application or faulty data from GPS (vTg--telegram) 19 vtG.h = Course value from GPS telegram DIP--Switch B20: positions 6,7 and 8 B22 17x B23 No telegram, DV--bus application, or faulty data from GPS (vTg--telegram) Edition: Sept. 05, 2005 67 3647.
Distribution Unit 138--118 Seq. No. 20 Indications Comments, Notes vhw = Speed value in knots from NMEA telegram (speed through water) B22 DIP--Switch B20: positions 6,7 and 8 18x B23 No telegram, DV--bus application, or faulty serial speed data (vHw--telegram) 21 SPd.A = Speed in knots (actual value) (or value from DV--bus) The speed for which the source has been selected, is displayed. B22 DIP--Switch B20: positions 6,7 and 8 19x B23 In case of a fault the last actual speed is displayed.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 22 Indications Comments, Notes PoS = Position -- latitude in degrees DIP--Switch B20: positions 6,7 and 8 B22 20x Automatic latitude from GPS or actual latitude from the DV bus B23 No latitude data available (GPS defective) or DV--bus application 23 ASPd = Alarm Speed B22 DIP--Switch B20: positions 6,7 and 8 21x B23 3 2 Digit 3 ”Speed OK” Digit 2 “ Speed Alarm Digit 1 “Auto Speed OK” Digit 0 “ Auto Alarm” Edition: Sept.
Distribution Unit 138--118 Seq. No. 24 Indications Comments, Notes PoSn = Latitude value derives from automatic latitude input. Indicated in degrees B22 DIP--Switch B20: positions 6,7 and 8 22x Actual latitude (or manual set latitude value) or automatic latitude from the DV bus B23 In case of a fault, the last actual latitude is displayed. 25 APoS = Alarm position input B22 DIP--Switch B20: positions 6,7 and 8 23x B23 0001 = no position (alarm) 1100 = position o.k. 3647.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No.
Distribution Unit 138--118 Seq. No. 28 Indications Comments, Notes nSGG = NMEA--telegram (strings of the GGA--telegram) B22 DIP--Switch B20: positions 6,7 and 8 26x B23 Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the number of characters. (1 display content = max. 4 ASCII--characters) See sequ. no. 29 3647.DOC010302 72 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 29 Indications Comments, Notes nSGL = NMEA--telegram (String of the GLL--telegram) B22 DIP--Switch B20: positions 6,7 and 8 27x B23 1x B23 Example Length of the telegram = 44 ASCII--characters 2x B23 3x B23 4x B23 5x B23 6x Edition: Sept. 05, 2005 73 3647.
Distribution Unit 138--118 Seq. No. cont. 29 Indications Comments, Notes nSGL = NMEA--telegram (Strings of the GLL--telegram) DIP--Switch B20: positions 6,7 and 8 B22 27x B23 7x B23 8x B23 9x B23 10x B23 11x B23 12x Checksum 3647.DOC010302 74 Edition: Sept.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. cont. 29 Indications Comments, Notes nSGL = NMEA--telegram (Strings of the GLL--telegram) DIP--Switch B20: positions 6,7 and 8 B22 27x B23 13x With the 1st operation of the contact switch B23, the number of ASCII--characters is displayed. If the display shows “0000”, no telegram--output took place. With every further operation of contact switch, 4 consecutive ASCII--characters are displayed.
Distribution Unit 138--118 Seq. No. 31 Indications Comments, Notes nShw = NMEA--telegram (Strings of the VHW--telegram) DIP--Switch B20: positions 6,7 and 8 B22 30x B23 1x Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the number of characters. (1 display content = max. 4 ASCII--characters) See seq. no.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 33 Indications Comments, Notes nSbw = NMEA--telegram (String of the VBW--telegram) B22 DIP--Switch B20: positions 6,7 and 8 31x B23 1x Number of ASCII--characters per telegram 0000 = no telegram The number of operations depends on the number of characters. (1 display content = max. 4 ASCII--characters) See seq. no.
Distribution Unit 138--118 Seq. No. 35 Indications Comments, Notes Development only! SCI . = Serial Communication Interface NMEA Log/ GPS input) DIP--Switch B20: positions 6,7 and 8 B22 33x B23 1x The content of the two digits is during a data transfer unrecognisable. Just the digits 1(16) and 0(16) are visible for a short moment; (10(16) means line feed). All other sequentially indicated values are for development purpose only.
Distribution Unit DISTRIBUTION UNIT 138--118 Seq. No. 37 Indications AAdd = Comments, Notes Alarm address of a defective Gyro compass DIP--Switch B20: positions 6,7 and 8 B22 35x B23 1x 0000 → no faulty Gyro otherwise the CAN address.
Distribution Unit 138--118 Seq. No. 40 Indications Comments, Notes dubS =Software version of the DV--bus processor of the Interface PCB B22 DIP--Switch B20: positions 6,7 and 8 38x B23 1x 41 UTC = Time of *ZDA--Telegram B22 DIP--Switch B20: positions 6,7 and 8 39x B23 1x Hours 2x Minutes Seconds 3x Day Month 4x Year With this signal the time for a connected course printer is synchronised. This UTC--signal normally is received via a GPS receiver.
Distribution Unit DISTRIBUTION UNIT 138--118 8.1 Table of DIP--switch functions 8.1.1 Adjustments DIP-switch Step Display Function Push button B23 (left) Push button B22 (right) 1+2 1 20 (address) CAN--bus address setting of Distribution Unit. Perform processor reset with B21 after changing address upwards downwards 4 1 MAGn Magnetic compass activation 2 MAGn Bring display to flash to activate input choose set 1 nME1 NMEA channel 1 configuration 2 nME1.
Distribution Unit 138--118 8.1.2 DIP-switch Step Display Function Push button B23 (left) 3 1 --ro-- RoT output scaling choose 2 r30 Select for 30°/minute choose set 3 r100 Select for 100°/minute choose set 4 r300 Select for 300°/minute choose set 5 Gy Select for analog heading output choose set Push button B23 (left) Push button B22 (right) Adjustments E10 DIP-switch Step Display Function 1+2 1 20 (address) CAN--bus address setting of Distribution Unit.
Distribution Unit DISTRIBUTION UNIT 138--118 DIP-switch Step Display Function Push button B23 (left) 1+2+3 1 Chn1 Output channels 1--8 data selection choose 2 HSEr Select for heading serial (LED red) choose set 3 nME1 Select for NMEA, 1/sec (LED green) choose set 4 nME2 Select for NMEA, 10/sec (LED blue) choose set 5 Chn2 6 HSEr Select for heading serial (LED red) choose set 7 nME1 Select for NMEA, 1/sec (LED green) choose set 8 nME2 Select for NMEA, 10/sec (LED blu
Distribution Unit 138--118 8.1.
Distribution Unit DISTRIBUTION UNIT 138--118 DIP-Switch Edition: Sept.
Distribution Unit 138--118 Intentionally left blank 3647.DOC010302 86 Edition: Sept.
Distribution Unit Type 138--118.NG001 ANSCHÜTZ 1 Ersatzteilkatalog SPARE PARTS CATALOGUE 2 5 3 4 Pos. Lager--Nr. Stock--No. Benennung Designation Zeichnungs.Nr. Part--No. Stck. Herst.--Code Versorgungs--Nr. Qty. MFRC NSN 1 3609431 Interface PCB, AT Interface PCB, recond 138--118.103 AT 1 D2865 2 3609430 I/O PCB, AT I/O PCB, recond 138--118.101 AT 1 D2865 3 1.
Distribution Unit Type 138--118.NG001, NG001 E10 ANSCHÜTZ 1 Ersatzteilkatalog SPARE PART S CATALOGUE 2 5 3 4 Pos. Lager--Nr. Stock--No. 1 3609701 Benennung Designation Interface PCB, AT 2 3609702 I/O PCB, AT 3 1.762017 G--Sicherungseinsatz 4 1760517 G--Sicherungseinsatz 5 1762137 G--Sicherungseinsatz Zeichnungs--Nr. Part--No. Interface PCB, recond. 138--118.100 AT E10.X01 I/O PCB, recond. 138--118.101 AT E10.