Instruction manual
19
4 Press the PF-1keyorholdthePF-1 or PF-2keytoprogram
thenewfunctionontothedesiredkey.
• AtonesoundsafterpressingthePF-1key,conrmingthatthe
function has been stored to the PF-1 press operation.
• TwotonessoundafterholdingthePF-1key,conrmingthatthe
function has been stored to the PF-1 hold operation.
• ThreetonessoundafterholdingthePF-2key,conrmingthat
the function has been stored to the PF-2 hold operation.
• ThepressoperationofthePF-2keycannotbereprogrammed.
Attempting to do so causes an error tone to sound.
5 Repeat steps 2 and 3 to reprogram additional functions.
6 Hold the PTT switch for 3 seconds to save the settings and
exit Setting mode.
Note: The transceiver will automatically return to normal operation if
no action is performed for 20 seconds.
PROGRAMMABLE FUNCTIONS
n
None
Nofunctionisprogrammedforthekey.
n
Low Transmit Power
Press to toggle the transmit power between high and low.
n
Monitor
PressthiskeytodeactivateQTorDQTsignaling.Pressthe
keyagaintoreturntonormaloperation.
n
Scan
PressthiskeytoturntheScanfunctiononandoff.
Scan is useful for monitoring signals on the transceiver
channels.Whenscanning,thetransceiverchecksfora
signal on each channel and only stops if a signal is present.
If the QT/DQT matches, the transceiver stops at the channel
andopensthesquelchsoyoucanlistentothecall.Ifthe
QT/DQT does not match, the call is ignored and scanning
continues.