Instruction manual

13
5 Press the PTT switch to save the setting and switch to the
QT/ DQT setting.
• Abeepwillsoundandthetransceiverannounces“QT”.
6 Press the Up/DownkeytoselectQTorDQT,thenpressthe
PTT switch to confirm the selection.
7 Press the Up/Downkeytoincrement/decrementtheQT/
DQT number, to select the new value.
• PressandholdtheUp/Downkeytocontinuouslyincrement/
decrement the QT/ DQT number.
• QT/DQTnumbersandtheircorrespondingsettingsare
provided in the tables on pages 15 to 17.
• AvoiceannouncementwillinformyouoftheselectedQT/DQT
number.
8 Press the PTT switch to save the setting.
• Abeepwillsoundandthetransceiverannounces“Channel
Number”.
• Repeatsteps3to8tosetupanotherchannel.
9 Press and hold the PF-2keyandPTT switch to store the
settings and return to normal operation.
Note:
The transceiver will automatically return to normal operation if
no action is performed for 20 seconds.
Frequenciesindicatedbyanasterisk*inthefollowingtable
maybesusceptibletointerferencefromotherfrequencies.
Ifinterferenceoccurs,changetoadifferentfrequencyinthe
following table.
Table Number
Operating
Frequency (MHz)
Table Number
Operating
Frequency (MHz)
0 OFF 9 461.0375
1 464.5000 10* 461.0625
2 464.5500 11* 461.0875
3 467.7625 12* 461.1125
4* 467.8125 13 461.1375
5 467.8500 14 461.1625
6 467.8750 15 461.1875
7 467.9000 16 461.2125
8 467.9250 17 461.2375