Design Guide
6
|
Cove Customer Care 800.222.7820
COVE DISHWASHERS
Plumbing
Installation must comply with all applicable plumbing codes.
Locate the water supply and drain within reach of the water
and drain connections, likely in an adjacent cabinet. Route
the water supply through the shaded area shown in the
illustration below. Connect the water supply line to a hot
water house supply with an easily accessible shut-off valve
between the supply and the unit.
PLUMBING REQUIREMENTS
Water Connection 5' (1.5 m) braided tubing with
3
/8" female compression tting
Drain Connection 5'
(1.5 m) corrugated tubing
Pressure 30–140 psi
(2–9.7 bar)
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply within reach of the power cord,
likely in an adjacent cabinet. Refer to the illustrations below.
A separate circuit servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) outlet or breaker may
be required, whichever complies with local codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 3'
(.9 m)
E
E
ELECTRICAL
LOCATION
IN ADJACENT
CABINET
FRONT VIEW
6"
(152)
2" (51)
TOE KICK
SIDE VIEW
BACK OF
OPENING
Electrical location
Electrical routing
6"
(152)
2"
(51)
TOE KICK
SIDE VIEW
BACK OF
OPENING
Water supply routing