Parts List/Tune Up Info

Voltage [V]
Voltage [V]
ADC Accuracy vs. VDDS
Vin = 1 V, Internal reference,
200 kSamples/s
1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8
1
1.001
1.002
1.003
1.004
1.005
1.006
1.007
1.008
1.009
1.01
D
067
Temperature [°C]
Voltage [V]
AD
C
Accuracy vs. Temperature
Vin = 1 V, Internal reference,
200 kSamples/s
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
1
1.001
1.002
1.003
1.004
1.005
1.006
1.007
1.008
1.009
1.01
D066
42
CC2642R
SWRS194G JANUARY 2018 REVISED APRIL 2020
www.ti.com
Submit Documentation Feedback
Product Folder Links: CC2642R
Specifications
Copyright © 2018–2020, Texas Instruments Incorporated
Figure 5-24. ADC Accuracy vs.
Temperature
Figure 5-25. ADC Accuracy vs.
Supply Voltage (VDDS)