Number Common
Fault
Cause Soluon
1
Rice is not
fully cooked
The rice to water ratio is off.
There is rice on the bottom of the
inner tank or on the surface of the
heating plate.
The bottom of the inner tank or
the surface of the heating plate is
deformed.
During the cooking process, the top
cover is not closed properly, causing
steam to leak.
The “cook” button was accidentally
disengaged during the cooking
process.
Adjust the rice to water ratio.
Refer to your recipe’s cooking
instructions.
Remove pieces of rice with
a dry cloth. Replace the
deformed inner tank or heating
plate.
Properly close the top cover.
Press the cooking button again.
2
Does not
turn on
The power supply is not connected
properly.
Check multiple outlets for a
power connection. Ensure your
outlet is properly wired for the
electrical specifications of the
machine.
3
Rice is
overcooked
The “cook” button was pressed again
after cooking.
There is excess rice on the bottom/
surface of the heating plate.
After the rice is cooked, do not
press the “cook” button again.
Remove excess rice with a dry
cloth.
4
Air leaks
from the
lid during
cooking
The top cover is not attached
correctly.
The edge of the inner pot is deformed.
Attach the top cover correctly.
Replace the inner pot.
Troubleshooting