Technical data
9190
Rising energy prices and better
sealed buildings mean that we
need mechanical ventilation with
heat recovery in our homes.
PRODUCT INFORMATION CV 200
CV 200
The CV 200 is the perfect venti-
lation unit for ventilating large
apartments or homes of up to
approx. 150 m
2
.
It is available in three different
models (R, L and C), each of
which have 4 versions - a total
of 12 variants of the CV 200.
Electrical connection 1 ~ 230 V + N + PE / 50 Hz
Duct connection Ø160 mm
Weight R & L: 72 kg, C: 66 kg
Heat exchanger Countercurrent exchanger (alu)
Filter F5 standard, F7 option
Colour RAL 9010 (white)
Current 1.2 A
Supply cable 1.5 mm²
Max. power consumption 160 W
Leakage current
7 mA
Dimensions (L/H/D)
L, R: 1222 x 303 x 861 mm
C: 1336 x 303 x 656 mm
ELECTRIC COMFORT HEATING SURFACE OPTION
Electrical connection, internal 1 x 230 V
Heating capacity 900 W
Thermal cut-out, aut. reset 70°C
Thermal cut-out, man. reset 120°C
WATER HEATING SURFACE OPTION
Max. operating temperature 90°C
Max. operating pressure 10 bar
Heating capacity 1000 W*
Pipe connection 1/2" (DN 15)
Material of pipes/louvres Copper/aluminium
Opening/closing time, motorised valve < 60 s
* Capacity at: supply/return temperature 60/40°C, water volume 43 L/h
STANDARD AND OPTIONS
MODEL
R
MODEL
L
MODEL
C
Bypass x x x
Electric preheating surface
• • •
Electric comfort heating surface
• • •
Water heating surface (comfort heating) – – –
CO
2
-sensor (wall-mounted)
• • •
CO
2
-sensor (integrated)
• • •
PIR/motion sensor
• • •
Electric humidity sensor
• • •
Condensate pump x x x
Cooling module – – –
Motorised exhaust damper
• • •
Motorised main damper
• • •
Countercurrent heat exchanger (alu) x x x
Energy Meter
– – –
x:standard•:option–:notavailable
TECHNICAL DATA
Capacity: CV 200 R CV 200 L CV 200 C
Maximum capacity
at 50 Pa external pressure drop
250 m
3
/h 342 m
3
/h 342 m
3
/h
Maximum capacity
at 50 Pa external pressure drop
and 1000 SFP W/(m
3
/s)
250 m
3
/h 273 m
3
/h 285 m
3
/h