Measurement type definitions
Measurement type Description Available units
LEVEL This is a display and an output function option. It is
the height from the bottom of the tank to the
surface of the liquid (Tank height - Distance).
m, cm, mm, in (inches), ft
(feet)
DISTANCE This is a display and an output function option. It is
the distance from the face of the flange (or thread
stop) to the surface of the liquid.
m, cm, mm, in (inches), ft
(feet)
CONVERSION This is a display and an output function option. It
gives the volume or mass of the tank contents.
This data is available if you prepare a volume or
mass table in configuration mode. For data on how
to prepare the conversion table, refer to How to
configure the device to measure volume or mass
on page 78. If the device is used with PACTware
software, it can also show flow rate in a channel. 6
flow profiles are available in the menu: Parshall
(ISO 9826), Venturi Rectangular (ISO 4359),
Venturi Trapezoidal (ISO 4359), Venturi U
(ISO 4359), V-Notch (ISO 1438) or Rectangular
Notch (ISO 1438).
m3, L, gal (US gallons), ImpG
(Imperial gallons), ft3, bbl (oil
barrel), kg, t, Ston, Lton, m,
cm, mm, in, ft, m3/h, ft3/h
ULLAGE CONV. This is a display and an output function option. It
gives the empty volume or remaining mass that
can be put in the tank. This data is available if you
prepare a volume or mass table in configuration
mode. For data on how to prepare the conversion
table, refer to How to configure the device to
measure volume or mass on page 78.
m3, L, gal (US gallons), ImpG
(Imperial gallons), ft3, bbl (oil
barrel), kg, t, Ston, Lton, m,
cm, mm, in, ft, m3/h, ft3/h
REFLECTION This is a display and an output function option. It is
the percentage of the emitted radar signal which
makes a reflection on the surface of the liquid and
is received by the device.
%
OUTPUT I (mA) The current output of the device. mA
OUTPUT I (%) The percentage of the current output. 0% = 4 mA.
100% = 20 mA.
%