Technical data
20
HB EML3020 A-(en)LevelWave LR01
3.5 Installation
3.5.1 Pressure and temperature ranges
For more data on pressure ratings, refer to Pressure ratings on page 101
DANGER!
If the ambient temperature is more than +70°C/ +158°F, there is a risk of injury if you touch the
device. Use a protective cover or metallic grid to prevent injury.
Figure 3-2: Pressure and temperature ranges
1 Flange temperature
Non-Ex devices: Depends on the type of antenna, process connection and the seal material. Refer to the table that
follows.
Ex devices: see supplementary operating instructions
2 Ambient temperature for operation of the display
-20...+60°C / -4...+140°F
If the ambient temperature is not between these limits, the display screen switches off automatically. The device con-
tinues to operate.
3 Ambient temperature
Non-Ex devices: -40...+80°C / -40...+176°F
Ex devices: see supplementary operating instructions
4 Process pressure
Depends on the type of antenna and process connection. Refer to the table that follows.
Antenna
type
Process
connection
Seal Process connection
temperature
Process pressure
[°C] [°F] [barg] [psig]
PP
Wave Horn
G1½;
1½ NPT
- -20...+100 -4...+212 -1...16 -14.5...232
PTFE
Wave Horn
Flange with
PTFE plate
- -50...+150 -58...+302 -1...40 -14.5...580
Metallic Horn
Wave Guide
Flange Metaglas® with
FKM/FPM
-40...+200
1
-40...+392
1
-1...40
2
-14.5...580
2
Metaglas® with
Kalrez® 6375
-20...+250
1
-4...+482
1
-1...40
2
-14.5...580
2
Metaglas® with
PFA
-60...+130
1
-76...+266
1
-1...40
2
-14.5...580
2
Metaglas® with
EPDM
-50...+130
1
-58...+266
1
-1...40
2
-14.5...580
2
1 Higher temperature on request
2 Higher pressure on request