Datasheet
MODEL
Output
DC Voltage Range
UP-500-12
Rated Current
Current Range (convection)
Rated Power (23.5CFM FAN)
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
12V
42A
0 ~ 33.3A
0 ~ 42A
150mVp-p
10.8 ~ 13.2V
±2%
±1%
±2%
600ms, 30ms at full load
16ms / 230VAC at full load
Input
Voltage Range
Frequency Range
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
90 ~ 264VAC, 127 ~ 370VDC
47 ~ 63Hz
90%
6A / 115VAC, 3A / 230VAC
30A / 115VAC, 50A / 230VAC
< 2mA / 230VAC
Protection
Over Voltage
Protection type: latch-off mode,re-power on to recover
Envi onmentr
Working Temp.
Working Humidity
Storage Temp. & Humidity
Temp. Coefficient
Vibration
-20 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.03% / °C (0 ~ 50°C)
10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. Each along X, Y, Z axes
Safety & EMC
Safety Standards
EMI Conduction & Radiation
Isolation Resistance
EMS Immunity
Harmonic Current
Withstand Voltage
I/P-O/P: 4242VDC, I/P-FG: 2121VDC 1minute
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Others
Cooling
Packing
1.43kg; 12pcs / 18.16kg / 0.89CUFT
Note.2
Note.3
Note.4
Power OK signal
Remote ON/OFF Control
Two modes setup remote ON/OFF (Please refer to Function Description of J2)
Dimension (WxHxD)
127x38x254 mm / 5.000x1.496x10.000 inch
Air convection for 400W, With23.5CFM Fan for 500W
Note.5
Over Temperature
95°C With N2 sense by T1 core ±5°C, 95°C With TH1 sense near D26 heat sink ±5°C
Rated Power (convection)
Rated Power (23.5CFM FAN)
399.6W
504W
UP-500-15
15V
33.5A
0 ~ 26.7A
0 ~ 33.5A
150mVp-p
13.5 ~ 16.5V
±2%
±1%
±2%
400.5W
502.5W
UP-500-24
24V
21A
0 ~ 16.7A
0 ~ 21A
150mVp-p
21.6 ~ 26.4V
±2%
±1%
±2%
400.8W
504W
UP-500-48
48V
10.5A
0 ~ 8.4A
0 ~ 10.5A
150mVp-p
43.2 ~ 52.8V
±2%
±1%
±2%
403.2W
504W
90% 90% 91%
Connection
I/P: 3P/9.5mm , O/P: 8P/9.5mm terminal block with coverterminal block with cover
Open Drain Max. 30VDC / 0.1A
Remote Voltage sense
Compensates for wire voltage drop
MTBF
Certified UL 60950-1; EN 60950-1
Certified EN 55022; EN 61000-6-3
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 61204-3; EN 55024; EN 61000-6-1; EN 61000-4-2, 3, 4, 5, 6, 8, 11
88.188K HRS Certified MIL-HDBK-217F
500W Single Output with PFC Function
UP-500 series
Protection: OVP, OLP, OTP, SCP
Power OK signal
Remote Voltage sensor
Selectable Remote ON / OFF Control
Active AC surge current limit
U-bracket low profile: 38mm
Withstand 2G vibration test
3 years warranty
Features:
Universal AC input / Full range
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that
it still meets EMC directives.
Note
REV. C5
13/07/03
1
Over Load
Hiccup mode: when the rated output power is within 105 ~ 150% for more than 3secs.
Constant current limit: > 150% rated power / short circuit
Auto-recovery: If O/P drop to 40% of the rated output voltage, PSU will shut down and auto-recover
5times (If fault condition remains after 5times recovery, PSU will shut down. User must re-power on to recover)
115 ~ 150% rated output voltage