Product Specifications

MODEL
SP-4000-124 SP-4000-148 SP-4000-224 SP-4000-248
100 / 110 / 115 / 120VAC 200 / 220 / 230 / 240VAC
±5%
Pure sine wave output
Power ON / OFF remote control (Green Terminal)
Remote controller CR-8 / CR-16A (optional)
Input & Output fully isolation
Temperature & Load controlled cooling fan
Built in advance microprocessor to provide friendly interface
REV. A6
16/07/27
1
AC Voltage
AC Regulation
4000W Pure Sine Wave Inverter
SP-4000 series
<8000VA
>4000VA~4600VA (100%~115%)
24VDC 48VDC 24VDC
21.0 ~ 33.0VDC 42.0 ~ 66.0VDC 21.0 ~ 33.0VDC
≤2.0A@24VDC
1.0A@48VDC
≤2.0A@24VDC
<0.2A@24VDC <0.1A@48VDC <0.2A@24VDC
91% 91% 90%
Input Under - Voltage Protection
21.0 ±0.5VDC 42.0 VDC±1.0 21.0 VDC±0.5
Output
Maximum Output Power (1 Min)
Output Waveform
Frequency
DC Voltage
Voltage Range
Input
NO Load Current
Power Saving Mode
Efficiency (Max.)
Protection
Input Under - Voltage Recovery
Input Over - Voltage Protection
Input Over - Voltage Recovery
Environment
Operating Temp.
Storage Temp.
Storage Temp. Humidity &
Output Overload
Output Short
Safety & EMC
Safety Standards
-30°C ~ +70°C
Shutdown output voltage, restart to recover
10 ~ 95% RH
Certified UL 458
Certified EN 60950-1
Others
Cooling
Packing
Application
Dimension (W x H x D)
10kg; 2pcs / 21.00kg / 3.05CUFT
Home and office appliances, portable power equipment, vehicle, yacht and off-grid Solar power
systems ...etc.
255x158x462 mm / 10.04x6.22x18.19 inch
48VDC
42.0 ~ 66.0VDC
1.0A@48VDC
<0.1A@48VDC
91%
42.0 VDC±1.0
EMC Standards
E-mark
Certified FCC class A NOTE3
----
Certified EN 55022 class A NOTE3; EN 55024
EN 61000-3-2, -3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
Certified CISPR 25
ISO 7637-2
Features:
4000VA
Surge Power ( 1 Sec )
Output frequency 50 / 60 Hz selectable by DIP switch
Output voltage DIP switch selectable
Adjustable power saving mode by variable resister
3-color LED status indicators
Input protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage
Output protection: Short Circuit / Overload / Over Temperature
E13 / UL / CE / FCC approved
±3%
Rated Power
50 / 60 Hz ±0.5%
Over Temperature
Heat sink temperature over 80
automatically after heat sink temperature goes down to 60°C ±5°C
°C ±5°C, shutdown output voltage, recover
DC Input Reverse Polarity
By fuse
25.0 ±0.5VDC 50.0 VDC±1.0 25.0 VDC±0.5 50.0 VDC±1.0
33.0 ±0.5VDC 66.0 VDC±1.0 33.0 VDC±0.5 66.0 VDC±1.0
29.0 ±0.5VDC 58.0 VDC±1.0 29.0 VDC±0.5 58.0 VDC±1.0
Shutdown output voltage, restart to recover
----
Control
&
Signal
Accessory (Optional)
Remote Control: CR-8 / CR-16A; Transfer Switch: TR-40
LED Indicator
Dry Contact Terminal
Remote Control Terminal
Input voltage level, output load level and faulty status
By relay
6-port green terminal
Socket Type
Note1 - Normal Condition: Vin=12.5V / 25V / 50V Vo=100 / 110 / 115 / 120 VAC 80% Full load (PF=1.0)
Note2 - Normal Condition: Vin=12.5V / 25V / 50V Vo=200 / 220 / 230 / 240 VAC 80% Full load (PF=1.0)
Note3 - Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Temperature & load controlled cooling fan
Pure Sine Wave (THD<5%@Normal Load NOTE1) Pure Sine Wave (THD<3%@Normal Load NOTE2)
Hard Wire
-20 ~ +40°C ; 60°C °C @40% power load

Summary of content (2 pages)