z Ignition Lockout function – The ignition lockout function is to turn OFF the Inverter when the auxiliary
input wiring is connected to the ACC with 12 Volts.
z Return Override Function – The Return Override Function is to turn ON the inverter when the auxiliary
input wiring is connected to the reversed gear shift with 12 Volts.
i Phone Jack Connector
1. Before connection, please make sure to switch the inverter to REMO position. (For SP series) (Fig.4)
2. Connect the RJ-11 cable between CR-16 remote and the inverter.
Fig.4 Phone Jack Connector
j JP1 The JP1 is to set either Return Override Function or Ignition lockout function.
z JP1 jumper “Short” - Return Override Function
Return Override Function – The Return Override Function is to turn ON the inverter when the
auxiliary input wiring is connected to the reversed gear shift with 12 Volts.
z JP1 jumper “Open” – Ignition Lockout Function
Ignition Lockout function – The ignition lockout function is to turn OFF the inverter when the auxiliary
input wiring is connected to the ACC with 12 Volts.
z The connector which is connected to AUX power must use with 12V / 0.5A fuse.
Trigged signal
JP1
Inverter
Status
AUX
1 Open OFF
0 Open ON
1 Short ON
0 Short OFF
Note default mode is Open.