Use and Care Manual

Please disconnect the power supply before cleaning
or conducting maintenance.
Auto Drainage: Connect water hose (≤13.12ft/4m length) to
the water drainage hole by quick connector, the machine will
automatically drain by water pump through water hose when
operating.
Cleaning: Clean the unit body with a soft damp cloth. Do not
submerse or place water on the unit or control panel. Water may
damage the electronic components of the unit. Do not use
chemical solvent such as benzene, alcohol, gasoline or other
heavy-duty cleaner. The surface may become damaged or
deformed.
Cleaning the Air Filter:
Step 1: Pull out the air filter gently.
Step 2: Use a vacuum cleaner to remove the dirt on the surface
of the air filter. If the air filter is exceptionally dirty, immerse it
gently into warm water (about 104/40) with a neutral
detergent, rinse and dry it thoroughly.
Step 3: Insert the filter back into the unit.
Dehumidifier Storage:
1. Push the purge button to empty the water before
transportation or storage.
2. Transport and store the machine upright.
3. Stack machines in warehouse to save space.
Defrosting Indicator: When the machine is
defrosting, this indicator turns on. After defrosting,
it turns off.
Water Full Indicator: When the water pump is full
of water, the indicator light turns on to remind the
user to drain.
Display Screen: The default temperature
display is Fahrenheit temperature. When
the machine is in standby mode, press the
power button for 5 seconds to switch to
Celsius temperature. When the machine is
running, it shows the temperature and humidity of the inlet air
and outlet air. It displays the running time when it is in running
mode; and displays the setting timing and setting humidity data
when users set .
Memory Function: If there is a power outage or the unit shuts
off, it will auto restart to its original settings except timing, once
power is restored.
Note:
When humidity of air inlet ≥ setting humidity data +3%RH, and
the compressor is out of 3 minutes delay start protection, the fan
will start immediately and the compressor will start in 3 seconds
later.
When humidity of air inlet ≤ setting humidity data -3%RH, the
compressor will stop working immediately, and the fan will stop
working in 1 minute later.
AUTO DRAINAGE & MAINTENANCE