Manual and User Guide
8 
 INSTALLATION INSTRUCTIONS  
WARNING! 
THIS APPLIANCE HAS TO BE INSTALLED BY A QUALIFIED INSTALLER.  
Improper installation, adjustments, alterations, service or maintenance can cause injury or 
property damage. Consult a qualified installer, service agent, or the gas supplier. 
Screwdriver 
Wrench 
T-handle wrench 
Tape measure 
Angle hexagon key 
Pencil 
Adjustable pliers 
Adjustable wrench 
Burner and Nozzle Specifications 
Liquid 
Towngas 
Burner 
Thermal Power 
Nozzle 
Flow 
Thermal Power 
Nozzle 
Flow 
(kw) 
1/100(mm) 
l/h 
(kw) 
1/100(mm) 
l/h 
Triple Ring Burner 
3.2 
92 
232 
3.2 
260 + 
sleeve
761 
Semi Rapid Burner 
1.75 
65 
127 
1.9 
175+ 
sleeve
460 
Auxiliary Burner 
1 
50 
73 
1.3 
140+ 
sleeve
313 
Supply 
Pressures 
Nominal 
(mbar) 
28~30 
10 
Minimum 
(mbar) 
20 
6 
Maximum
(mbar) 
35 
20 