PROXIMITY TO SIDE CABINETS 
Important:   Base cabinet construction must allow for size of cooktops cut-out. 
1. Gas line opening: 
Wall-anywhere 11” 51/64(300mm) below underside of countertop; 
Cabinet floor – anywhere 3”1/8(79.2mm) from the rear wall. 
Grounded outlet: the electric cord with 3-prong ground plug has a length of 48”(122mm).Grounded outlet 
should be located within 36”(914.4mm) of right rear corner of cut-out. 
2. The cooktops CANNOT be installed directly adjacent to sidewalls or tall cabinets or tall appliances or 
other side vertical surfaces. There must be a minimum of 7” 7/8(200mm) side clearance from the cooktops 
cut-out to such combustible surface to both sides above the counter height. 
3.The maximum upper cabinet depth recommended is 13(330mm). Wall cabinet above the cooktops must be 
a minimum of 30”(762mm) above the countertop for a width of minimum 11” 13/32(290mm); it has to be 
centered with the cooktops. Side wall cabinets above the cooktops must be a minimum of 18”(457mm) 
above the countertop. 
4.A separating panel shall be provided under the cooktops as described in fig.4.2. 
FASTENING THE COOKTOPS(fig.4-3) 
Each cooktops is supplied with a set of tabs and screws to fasten it on units with a working surface from 3 to 
4cm deep. 
The kit includes 4 tabs “A” and 4 self-threading screws “B”. 
!  Cut the unit. 
!  Stretch gasket “C” over the edge of the hole made, be careful to overlay the junction edges. 
!  Put the cooktops into the hole cut into the unit and position it correctly. 
!  Put tabs “A” into place and tighten screws “B” until the cooktops is completely secured. 