■ Gas valve - The valve is not open.
Make sure the valve is completely open. 
■ Gas pipe - There may be air in the gas pipe.
Ignite repeatedly until flame catches. 
■ Burner cap
−  The burner cap is not placed correctly. 
o Replace the burner cap.
−  Some holes in the lid are stocked. 
o Clean the holes of the lid.
■ Spark pin - The spark pin is wet or contaminated by the food.
Clean and dry the spark pin.. 
■ Gas connecting pipes - The gas connecting pipes are stocked or squashed.
Contact a qualified technician. Adjust or change the connecting pipes. 
THE FLAME GOES OUT DURING OPERATION 
■ Thermocouple
−  The safety device is contaminated. 
o Clean the thermocouple.
−  The flame is so little that it can’t touch the thermocouple 
o Adjust the flame a little bigger. See the “Proper Burner Adjustments” section.
STRAN
GE SMELL 
■ Gas leaking -
 Contact a qualified technician 
−  The gas supply pipe 
is old and broken. 
o The main burner is not lit.
−  Change the gas supply pipe. 
o Ignite again after there is no strange smell.