Owner Manual
TESTING FL
AME STABILITY 
Test 1——Turn t
he knob from “HI” to “LO” quickly. If the upper row of flames goes out at this setting, 
increase the flame size and test again. 
Test 2——With the burner on “LO”, open and close the cabinet door under the range. If the flame is 
extinguished by the air currents created by the door movement, increase the flame height and test 
again. 
D.  FLAME RE-CHECK 
After the adjustment is made, turn all burners off. Ignite each burner individually. Observe the flame 
at the “HI” position. Rotate the knob to the lowest setting and be sure that the flame size decreases 
as the knob is rotated counter-clockwise. 
Adjust the hei
ght of top burner flames. The range “low” burner flame should be a steady blue flame 
approximately ¼" (0.64 cm) high. 
 Once the conversion has been completed and has passed testing, fill out the conversion 
sticker and include your name, organization and the date conversion is made. Apply the 
sticker near the appliance gas inlet opening to alert others in the future that this appliance has 
been converted. If converting back to Natural Gas, please remove the sticker so others know 
that the appliance is set to use its original gas. 
30