Owner Manual
Gas Supply Requirements 
EXPLOSION
 HAZARD 
Use a new CSA International approved gas 
supply line. 
Install a shut-off valve. 
Securely tighten all gas connections. 
If connected to LP, have a qualified person 
make sure gas pressure does not exceed 
14" (36 cm) water column. 
Examples of a qualified person include: 
−  Licensed heating personnel 
−  Authorized gas company personnel 
−  Authorized service personnel 
Failure to do so can result in death, 
explosion, or fire. 
• Observe all governing codes and
ordinances. 
IMPORT
ANT: This installation must conform 
with all local codes and ordinances. In the 
absence of local codes, installation must 
conform with American National Standard, 
National Fuel Gas Code ANSI Z223.1 - latest 
edition or CAN/CGA B149 - latest edition. 
IMPORT
ANT: Leak testing of the range must 
be conducted according to the manufacturer’s 
instructions. 
Type of Gas 
NATURAL
 GAS: 
−  This range is designed for use with 
Natural gas or, after proper conversion, 
for use with LP gas. 
−  This range is factory set for use with 
Natural gas.  The model/serial rating 
plate has information on the types of 
gas that can be used. If the types of 
gas listed do not include the type of gas 
available,
 check with the local gas 
supplier. 
LP GAS CONVERSION: 
−  Conversion must be done by a qualified 
service technician. 
−  No attempt shall be made to convert 
the appliance from the gas specified on 
the model/serial rating plate for use 
with a different gas without consulting 
the serving gas supplier. 
13