Full Product Manual
Installation
Important: the power supply to the appliance must be cut off before any adjustments or maintenance work is
done on it.
Installation of Built-in Ovens
To ensure the proper working order of the built-in appliance, the kitchen unit must be of a suitable size.
The sizes of the unit for installing the cooker under a worktop or in a column unit are shown in figure.
To provide adequate ventilation, there must be appropriate ventilation openings in the front bottom and the top
part of 31 in
2
, and an exhaust opening on the bottom of an least 31 in
2
, and an exhaust opening of at least 9.3
in
2
.
The unit panels next to the cooker must be heat resistant. In the case of veneered wood units, glues must be
resistant to a temperature of 248 F.
In accordance with safety standards, once the appliance has been mounted, there mus
t be no possible contact
with electrical parts. Any protective parts must be secured so that they can only be removed with the use of tools.
Fastening the oven
Insert the appliance into the compartment; open the oven door and fasten the oven to the cabinet using the four
screws “A”, remembering to place the special spacers provided between the hole and the screw itself.
27.95”
23.15”
22.72”
21.26
21. 65”
21. 65”
1.97”
1.97”
23.00”
27.2”
29.5”
23.15”
0.89”