INSTALLATION INSTRUCTIONS
9
INSTALLATION / CLEARANCES (Continued)
Installation in an island
NOTE: There must be a minimum of 6” (15.2 cm) clearance from the rear of the cooktop to
a combustible wall. Clearances from non-combustible materials are not part of the ANSI
Z21.1 scope and are not certified by CSA. Clearances to non-combustible materials must
be approved by the authority having jurisdiction.
This cooktop may be installed directly adjacent to existing 36” (91.4 cm) high base
cabinets.
The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side clearance from the cooktop to such combustible surfaces
above the 36” (91.4 cm) counter height.
Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4
cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this
6” (15.2 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
Wall cabinets above the cooktop must be a minimum of 42” (106.7 cm) above the
cooktop cooking surface for the full width of the cooktop. This minimum height
requirement does not apply if a cooktop hood is installed over the cooking surface.
ELECTRICAL REQUIREMENTS
Cosmo Gas Cooktop requires 110 volts, 50/60 Hz electrical supply to operate the ignition
system.
The power cord is a 3-prong grounding plug. The plug must be plugged into a mating
outlet.
Make sure there is a power outlet within the reach of the range top’s power supply cable
(within 36"/30cm from the right side of the range top). The outlet should be accessible
with the range top installed.
Cooktop must be properly grounded for safe operation.
DO NOT ground the cooktop to any of gas line/gas pipe.