Owners Manual

INSTALLATION INSTRUCTIONS
8
INSTALLATION / CLEARANCES
All units must be installed in accordance with the minimum rear and side wall clearances
and clearances extended vertically above the cooktop which are stated on the serial plate
(the serial plate is located on the back of the unit.)
Make sure that the wall coverings, countertops, and cabinets around the cooktop can
withstand temperatures of up to 200˚F / 93˚C generated by the cooktop. It is the
responsibility of the installer to make certain that the cooktop is properly adjusted at the
time of installation. Situations caused by improper adjustments or improper installation are
not covered under the warranty. Any expenses incurred due to such situations will not be
paid by the manufacturer of the appliance.
Installation without a range hood
NOTE: All measurements are based on 24” (61 cm) deep cabinet
This cooktop may be installed directly adjacent to existing 36” (91.4 cm) high base
cabinets.
The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side clearance from the cooktop to such combustible surfaces
above the 36” (91.4 cm) counter height.
Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm),
the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2
cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
Wall cabinets above the cooktop must be a minimum of 42” (106.7 cm) above the cooktop
cooking surface for the full width of the cooktop. This minimum height requirement does
not apply if a range hood is installed over the cooking surface.
CAUTION!: Items of interest to children should not be placed in cabinets above the
cooktop. Children climbing on the cooktop to reach items could be seriously injured.
Installation with a range hood
NOTE: Minimum clearance for the back wall is 0” with backsplash (backguard) or high
shelf.
If a range hood is installed above the cooktop, maintain a 30” (76.2 cm) minimum
clearance between the cooktop and the bottom of the range hood.
The range hood must exhaust outside.
For best smoke elimination, the minimum clearance of the range hood should be installed
30” to 36” above the cooktop surface. Recommended CFM should be 600 CFM for the 30”
cooktop.
Do not install with a downdraft ventilation system.
(Continued on next page)