INSTALLATION INSTRUCTIONS
Your cooktop is shipped from the factory set for
use with NG. It can be converted for use with LP
by following steps below.
(NOTE: The agency performing this work assumes
responsibility for the conversion.)
1.) Unscrew, by hand, the upper metal stopper of
the regulator.
2.) Unscrew, by hand, the white plastic piece
screwed under the above-mentioned metal
stopper. Next, screw back in the white plastic piece
in the OPPOSITE way under the metal stopper (For
gas reference, see the written “LP” and “NAT” with
relative indicating arrows on the white piece).
3.) Screw back in, by hand, the metal stopper in
the original position on the regulator.
NATURAL GAS (NG) TO LIQUEFIED PETROLEUM (LP) GAS CONVERSION (Continued)
Pressure Regulator Adjustment for Gas Conversion
The pressure regulator supplied with the cooktop is a convertible pressure regulator for use
with Natural Gas (NG) at a nominal outlet pressure of 4” W.C., or Liquefied Petroleum Gas
(LP) at a nominal outlet pressure of 10” W.C.
B = 1.89 in.
D = 7.91 in.