Owners Manual
14
INSTALLATION INSTRUCTIONS
CONNECTING TO GAS COOKTOP (continued)
To prevent gas leaks, use pipe joint compound resistant to NG gases on all-male external
pipe threads.
1.) In an easily accessible location, install a service manual gas shut-off valve. Be sure
everyone operating the cooktop knows where and how to shut off the gas supply to the
cooktop.
2.) Use a flexible gas line to connect to the 1/2” fitting, located on the bottom right-
hand corner underneath the cooktop. For gas inlet position, refer to diagrams below.
3.) When all connections have been made, be sure all cooktop controls are in the OFF
position and turn on the main gas supply valve. Check for gas leaks by using a 75%
water, 25% dishwashing soap solution. If a gas leak is present, shut off the gas
immediately, tighten all connections, and retest for leaks.
NOTE: Any opening in the wall behind the appliance and in the floor under the appliance
shall be sealed.
A = 3.01 in.
B = 2.56 in.
E = 5.37 in.
F = 4.05 in.
B = 1.89 in.
D = 7.91 in.