User Manual
14 15
• Disconnect the cooktop and its individual shut-off valve from the gas
supply piping system during any pressure testing of that system at test
pressures greater than 1/2 psig (3.5 kPa).
• Isolate the cooktop from the gas supply piping system by closing its
individual shut-off valve during any pressure testing of the gas supply system
at test pressures equal to or less than 1/2 psig (3.5 kPa).
3- CONNECT ELECTRICAL
A. Check to be sure the receptacle is properly grounded.
B. Plug in the power cord.
ASSEMBLE BURNERS, CHECK IGNITION
The electrode of the electronic ignition system is positioned above the surface
of the burner base. Do not remove a burner cap or touch the electrode of
a burner while another is turned on. Damage or electrical shock may occur.
A) The electrode of the electronic ignition system is positioned above the surface
of the burner base. Do not remove a burner cap or touch the electrode of a
burner while another is turned on. Damage or electrical shock may occur.
B ) Place burner heads over the burner base. Make sure the hole in the burner
head is properly aligned with the electrode in the burner base.
C ) Place the burner caps on the burner heads. Make sure that the burner
caps are properly seated on the burner heads. Burner cap properly seated
Burner cap not properly seated.
IMPORTANT: If the igniter electrodes continue to spark after all of the burners
are lit, check that each burner component is assembled and properly seated.
• Never reuse old flexible connectors. The use of old flexible connectors can
cause gas leak and personal injury. Always use new flexible connectors
when installing a gas appliance.
• To reduce the possibility of gas leaks, apply Teflon tape or a thread
compound approved for use with LP or Natural gas to all threaded
connections.
• Do not use a flame to check for leaks.
WARNING
Auxiliary Burner
Semi-Rapid Burner Rapid Burner Triple Ring Burner
The gas inlet is located on the bottom of the burner box at the rear and center.
Make gas connection through rear wall, or on cabinet floor at rear, as
illustrated.
1. Install the house gas supply at least 1” from the back wall.
2. Locate the electrical outlet 12” below the countertop.