Installation Guide
INSTALLATION GUIDE
This appliance can be used with Natural Gas and LP Gas. It is shipped 
from the factory adjusted for use with Natural Gas. Propane conversion 
kits can be purchased separately.
The maximum inlet gas supply pressure incoming to the gas appliance 
pressure regulator is 20’’ water column (5 kPa)
The minimum gas supply pressure for checking the regulator setting 
shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold 
pressure to the appliance (this operating pressure is 
4” w.c. (1.00 kPa) for Natural Gas and 10” w.c. (2.75 kPa) for LP Gas).
ATTENTION
A manual valve shall be installed in an accessible location in the gas 
line external to the appliance for the purpose of turning on or shutting 
off gas to the appliance
WARNING: Do not use aerosol sprays in the vicinity of this appliance 
while it is in operation
INSERTING THE COOKTOP
After having removed the various loose parts from the internal and 
external packing, make sure that the cooktop is not damaged and is
suitable for the specific gas usage. The gas type label is on the 
underside of the cooktop base.
In case of doubt, do not use the appliance and contact skilled 
personnel.
Keep all the packaging parts (polystyrene foam, cardboard, staples,
etc.) away from children.
Consider the critical dimensions of the appliance, before making an 
opening in the top surface of the countertop. (relative measurements
as per Fig 1- 2).
5










