MANUAL SHUT-OFF VALVE
THIS VALVE IS NOT SHIPPED WITH THE APPLIANCE AND MUST BE
SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed in the gas service line between the
gas hook-up on the wall and the appliance inlet, in a position where it can be
reached quickly in the event of an emergency.
In Massachusetts: A T handle type manual gas valve must be installed in the
gas supply line to this appliance.
FLEXIBLE CONNECTIONS
In case of installation with flexible couplings and /or quick - disconnect fittings
, the installer must use a heavy-duty, AGA design -certified commercial
flexible connector of at least 1/2" (1.3 cm) ID NPT
(with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69
standards.
In Massachusetts: The unit must be installed with a 36" (3-foot) long flexible gas
connector.
In Canada: use CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.
9 M79 quick disconnect device for use with gas fuel.
PRESSURE TEST-POINT STOPPER VALVE
To avoid gas leaks, the pressure test-point stopper valve and gasket supplied
with the range must be installed on the gas fitting at the back of the range
according to the diagram below
INSTALL GUIDE