Installation Guide
26
2. Insert the bare neutral (white) wire end through the lower center terminal
block opening.
3. Insert the two side bare wire ends into the lower left and the lower right
terminal block openings.
4. Tighten the 3 terminal screws securely into the terminal block, and
replace the terminal block access cover.
4-WIRE CONNECTION: CONDUIT
Use this method for:
• New branch-circuit installations (1996 NEC)
• Mobile homes / Recreational vehicles
• Areas where local codes prohibit grounding through the neutral
• The neutral wire of the supply circuit must be connected to the neutral
terminal located in the lower center of the terminal block. The power
leads must be connected to the lower left and the lower right terminals
of the terminal block. The grounding lead must be connected to the
frame of the range with the ground screw. Failure to do so can result in
electrical shock, severe personal injury or death.
WARNING
BLACK
RED
WHITE
GREEN
Remove or cut
ground strap